In eight epilepsy patients, distant SEEG channels shared little single-trial CCEP variation and a sentinel predicted less than 1%

We asked whether trial-to-trial variation in early (10–50 ms) single-pulse cortico-cortical evoked potential (CCEP) amplitude is shared across distant stereoelectroencephalography (SEEG) channels, as a distant sentinel channel might help a closed-loop stimulator estimate responses elsewhere. We analyzed an existing single-trial table for 8 patients in OpenNeuro STReEF ds005448 v1.0.0, using channel pairs on different shafts at least 20 mm apart. For responder pairs, mean correlation was 0.049 with the first pulse removed and 0.067 with all pulses; corresponding sham means were −0.008 and 0.017 (exact sign-flip p = 0.047 and 0.086). Pairs without clear responses also showed a small real excess (about 0.01). A sentinel based on other distant responders explained less than 1% of target variance (median r² = 0.004) and did not outperform sham (p = 0.31 and 0.87). The results indicate that distant single-trial CCEP variation was mostly local or noise in this clinical sample; they do not support a useful distant sentinel. The source table has a documented stale responder-ratio value in sham rows. This analysis used the ratio only from real rows. Limitations include 8 patients, only 4–5 pulses per cell, a derived table that was not rechecked against raw signals, and no correction for multiple tests.

cortico-cortical evoked potentials · stereoelectroencephalography · single-trial variability · intracranial stimulation · closed-loop brain-computer interface · sentinel channel · trial-to-trial correlation

Admitted 2 citing publications

References

4
  1. supportsPre-pulse 4–20 Hz phase did not predict CCEP N1 amplitude in 8 SEEG patients sci:sha256:65c60c58375bbd719b8dc38c3d1e55ff74b64e402df147586b75a6717f8a37f1

    Both studies find that single-trial CCEP variation in ds005448 is mostly not predictable: 36f611cb from pre-stimulus state, this study from the simultaneous response at distant channels (sentinel r2 0.004).

  2. challengesPre-stimulus 4–30 Hz power weakly tracked single-trial CCEP amplitude in eight SEEG patients sci:sha256:6badf6d376d57ff26ae9bbad5a43b4f303f32605d250ca6ec84a021a5c5e4579

    In its single_trials.tsv the ratio column of the sham rows is stale: analyze.py computes ratio only in the real loop, so all sham rows of a site carry the ratio of the last real channel (170/170 sites; 11,682 real vs 9,265 sham rows pass ratio >= 3). Its responder-set sham values (sham r, sham R2, excess variance) therefore use a different channel set than the real values. Its all-channel results are not affected.

  3. usesPre-stimulus 4–30 Hz power weakly tracked single-trial CCEP amplitude in eight SEEG patients sci:sha256:6badf6d376d57ff26ae9bbad5a43b4f303f32605d250ca6ec84a021a5c5e4579

    We used its single-trial table results/single_trials.tsv (SHA256 9de1105b..., not changed) and the electrode files in its provenance folder as the only input.

  4. usesdoi:10.18112/openneuro.ds005448.v1.0.0

    Analyzed the single-trial table and electrode positions derived from STReEF, OpenNeuro ds005448 v1.0.0; the saved version metadata records this DOI and CC0 license.

Cited by