A fixed 167.43-day clock gives lower 2023–2026 MAXI errors for 4U 1820-30 than the published clock with a period decrease when early Fourier profiles are fixed
We test two published central clocks for the long X-ray brightness cycle of 4U 1820-30. One clock has a past period step and a later period of 167.43 days. The other has a steady period decrease. We fit separate Fourier profiles to public daily data through MJD 60157. We hold each clock and profile fixed for later data through 2026 October 19. On 937 later MAXI 2–20 keV measurements, the weighted root mean square errors are 0.30084 and 0.39307 photons per square centimetre per second. The fixed-clock error is 23.5% smaller, and 7.4% below a constant early-mean forecast. The fixed clock has smaller MAXI errors in all 18 sensitivity fits. Removing any one full test cycle keeps the mean squared error difference positive. Paired cycle-block resampling and joint early/later resampling give positive descriptive intervals. Swift BAT gives a small, unresolved difference and has strong early weight concentration. A free-period fit to the later MAXI data gives about 170 days, without a period uncertainty. Thus the result does not establish a true period of 167.43 days. It compares fixed central forecasts and does not propagate the published clock parameter errors. It does not select a physical cause or exclude either full model family. The package preserves input data, provenance, code, daily forecasts, checks, tables, and figures.
4U 1820-30 · MAXI · Swift BAT · superorbital cycle · X-ray binary · forecast test · public data
References
3- usesdoi:10.3847/1538-4357/adaded
Equations 5 and 6 supply the two fixed central clocks. Table 4 supplies an alternate phase check. The reported data end sets our early/later split.
- usesdoi:10.1088/0067-0049/209/1/14
We use the public Swift BAT daily transient-monitor data and its documented quality flag and error columns.
- usesdoi:10.1093/pasj/61.5.999
We use public MAXI GSC daily flux data for the primary later-data comparison.
Cited by
6 publicationsPublic catalog entries on Sciscape.
- usesMatched MAXI and BAT data show lower daily flux correlation in 2023–2026 than in 2012–2023 for 4U 1820-30
We use its historical boundary at MJD 60157 and its warning about BAT weight concentration. We fetch source data directly and write new code. The observations overlap.
- usesA half-cycle window shift changes whether a two-harmonic mean loop interval contains zero for 4U 1820-30 in 2009–2026 MAXI data
We use its frozen native MAXI daily data file and original retrieval record. We write new code for paired-band cycle areas.
- usesResidual blocks change the 167.43-day clock test for 4U 1820-30 in 2023–2026 MAXI data
We use its later-sample definition and follow up its descriptive 169.99-day period estimate. We add conditional period ranges and full-search null tests with separate code on the same 937 observations.
- usesExcluding two BAT days reverses the 2024–2026 cubic and sine clock ranking for LMC X-4 with fixed four-harmonic profiles and inverse-variance fits
We use its fixed Fourier-profile forecast design and formal-weight checks. Our code is a separate implementation.
- LMC X-4 profiles stay early in the tested 2024–2025 BAT and MAXI data under a fixed phase model
This related X-ray clock study discusses fitting weight concentration. We independently check that issue in LMC X-4.
- usesTwo fixed SS 433 profiles fitted before 2024 give 0.61% lower 2024–2026 BAT weighted RMS error at 162.375 than at 162.15 days
Uses the chronological fixed-profile prediction test as a method reference. That work tested another source and instrument. We wrote new code and downloaded new data; no supporting files were reused.