Four GO time limits change group coefficients by less than 2.5 ms in 124 ds000030 participants.
We examined whether removing very short correct GO response times changed diagnosis group coefficients in the OpenNeuro ds000030 version 1.0.0 stop-signal task data. The analysis used 124 participants in 13 schedules that included all four diagnosis groups, and fit schedule, diagnosis, age, and gender terms. We removed times below 100, 150, 200, and 250 ms, keeping values at each limit. The largest absolute coefficient change was 2.418127651583288 ms, for BIPOLAR at 150 and 200 ms; those limits gave the same result because no accepted time fell between them. All 12 Bonferroni family 95% intervals for changes contained zero, and some intervals included absolute changes greater than 2.5 ms. The results describe this data release, model, and common-schedule sample. They do not identify guesses or recording errors, establish a causal diagnosis effect, or validate stopping-time measures. The source ReactionTime unit and event conversion remain assumptions. Errors may be dependent within schedules, which can affect the intervals.
stop-signal task · GO response time · reaction time · sensitivity analysis · diagnosis groups · OpenNeuro · ds000030 · HC3 · confidence intervals
References
5- usesAll three unadjusted GO time differences decrease when the ds000030 1.0.0 sample changes from 265 participants to 124 with common task schedules. sci:sha256:85ecc2d7049ddc560d12edfbe8c728498350e8579eb3bd6192325afaa22f7ceb
Its event tables, source manifest, schedule rule, participant means, and base model values let the new code compare four GO time limits with the earlier result.
- usesdoi:10.18112/openneuro.ds000030.v1.0.0
The analysis uses event tables and participant metadata from OpenNeuro ds000030 version 1.0.0.
- doi:10.1038/sdata.2016.110
- doi:10.3758/s13414-023-02752-y
- doi:10.7554/eLife.46323
Cited by
2 publicationsPublic catalog entries on Sciscape.
- usesThe SCHZ coefficient for upper GO time spread is 0.06652 source units in 124 ds000030 participants.
Its fixed event tables, source manifest, complete Git tree, common-schedule rule, mean-model outputs, and inspected retrieval code enabled the paired percentile calculation and numerical mean check. Its 100 ms rule enabled the fixed sensitivity calculation.
- usesAll three diagnosis contrast intervals for GO time change contain ±0.020 source units in 124 ds000030 participants.
Used its 100 ms correct-GO time limit as an additional response rule. This enabled a direct check of that limit on the paired half-change contrasts.