All three diagnosis contrast intervals for GO time change contain ±0.020 source units in 124 ds000030 participants.
In 124 participants from OpenNeuro ds000030 version 1.0.0, we compared diagnosis differences in correct GO response-time change between the first and second halves of a stop-signal task run. We selected common event schedules before outcome exclusions, used 13 of 39 schedules, and fit paired ordinary least squares models with schedule, diagnosis, age, and source gender terms. All three Bonferroni 95% confidence intervals for patient-minus-control change contained both ±0.020 source units; the individual 95% intervals did too. On the assumed seconds scale, these bounds are ±20 ms. The precision condition was therefore not met, and the intervals do not show equality or a diagnosis cause. The analyzed common sample included 46 control, 25 ADHD, 25 bipolar, and 28 schizophrenia participants. Results use correct GO responses only, and response-time units are assumed because the source field has no explicit unit declaration. This is one run per participant, not a repeat-session reliability study; the selected sample was not checked for similarity to a clinical population. The source reports no further common-sample exclusion for age or source gender and retains sensitivity results, schedule-removal ranges, checks, and limitations in the full text and supporting files.
stop-signal task · GO response time · diagnosis · temporal change · confidence intervals · precision · OpenNeuro ds000030
References
7- usesMean temporal half-run SSRT is at least 10 ms from full-run SSRT in 11 of 102 selected ds000030 runs. sci:sha256:36fb5f06074b933615cf2bf61f06b40034ed65f51a017cb9f571c32bdf68176e
Used its first-64 versus last-64 active-trial division rule. This enabled a temporal-half comparison with 48 GO and 16 STOP trials in each half. Its SSRT scores and selected sample were not reused.
- usesAll three unadjusted GO time differences decrease when the ds000030 1.0.0 sample changes from 265 participants to 124 with common task schedules. sci:sha256:85ecc2d7049ddc560d12edfbe8c728498350e8579eb3bd6192325afaa22f7ceb
Used its event tables, pinned source manifest, common-schedule rule, and full-run output values. These inputs enabled paired half calculations on the same 124 participants and numerical checks against the full-run model.
- usesFour GO time limits change group coefficients by less than 2.5 ms in 124 ds000030 participants. sci:sha256:0b3c9fa4ef012d9e956d0ced45bdc00ed82e316b3f6e56907a67c84de03f58ad
Used its 100 ms correct-GO time limit as an additional response rule. This enabled a direct check of that limit on the paired half-change contrasts.
- usesdoi:10.18112/openneuro.ds000030.v1.0.0
Analyzed event tables and participant metadata from the pinned ds000030 version 1.0.0 source; source manifests preserve the file hashes and Git commit.
- doi:10.1038/sdata.2016.110
- doi:10.7554/eLife.46323
- doi:10.1002/hbm.25347
Cited by
0 publicationsPublic catalog entries on Sciscape.