A ridge penalty of one gave no clear beta coherence gain above a phase control after one minute of training in 19 SEEG records
We tested a fixed ridge penalty of one in 19 public SEEG records from OpenNeuro ds003876 version 1.0.2. One minute set the complex channel weights. The next minute tested beta coherence at 13 to 29.5 Hz. We subtracted the exact conditional mean under independent group phase rotations. With equal patient weight, the score gain over unrestricted canonical coherence was 0.003360. The 95% patient bootstrap interval was -0.004486 to 0.016331. Seven patients gained and 12 lost. The two-sided sign-flip test gave p = 0.951271. It assumes independent patients and symmetric null contrasts. This result gave no clear gain. It does not prove equal performance. A secondary 20-second fit showed a gain, but its unrestricted weights were often nonunique. A second BLAS build preserved the primary result and changed some 20-second baseline scores. The package gives all test cells, primary weights, code, and results. Fresh public byte downloads rebuilt all 4,222,800 source coefficients exactly. The package preserves source pins, hashes, retrieval recipes, and reproduction commands. This test uses one selected record per patient and one time split. It does not establish neural interactions or a clinical marker.
ridge regularization · squared coherence · phase control · stereoelectroencephalography · SEEG · intracranial EEG · beta band · canonical coherence · rank · patient bootstrap · OpenNeuro · reproducibility
References
6- usesThe common-reference-invariant beta component contributed more to agreement in 19 adjacent-minute SEEG records sci:sha256:f0d64ceacebda1587fbb8cf20d8bc531c139cbd98608e6166f45e2a4738cfa1d
This publication is the source of the public Fourier inputs and quality records inherited through the rank audit. It enabled the selected 19-patient comparison.
- usesReference choice reduced mean 80 to 150 Hz rank agreement more than time change in 19 public SEEG records sci:sha256:16d6a5e5126b007f6f6be4f042d829df32ccd751f41bcfda4c9b9a3f5a80fce2
Its EDF helper, inherited through the data publications, enabled pinned byte retrieval, physical signal decoding, contact matching, and source time checks.
- usesSample rank forced 92.8 percent of unrestricted complex canonical beta coherence scores to one in selected 20-second SEEG samples from 19 patients sci:sha256:32fd9b2dcef61781cc6d5987c2db0808052487e232705a6208abd3c87ce55a3c
This rank audit supplied the 19 Fourier archives, selection rules, quality checks, byte recipes, and retrieval code. We used them for the fixed ridge comparison. We also reproduced its 60-second unrestricted test scores.