sciscape Publications
← All publications

Sample rank forced 92.8 percent of unrestricted complex canonical beta coherence scores to one in selected 20-second SEEG samples from 19 patients

We tested unrestricted complex canonical squared coherence in selected interictal SEEG records from 19 patients in OpenNeuro ds003876 version 1.0.2. The estimator fitted separate complex channel weights at each beta frequency. In 20-second samples, the sum of the two signal ranks exceeded the ten spectral observations for 931 of 1,003 contact group pairs. This rank condition forced 31,654 of 34,102 scores to one. All 20 independent contact phase controls gave the same count. The mean fitted score was 0.99369. Fixed weights gave a mean score of 0.04036 on a separate minute. These means gave each patient equal weight. A fixed three-channel reduction removed the forced values at this record length. Fitting bias remained below the rank limit. The rank limit is established linear algebra; the new result is its measured extent in these public records. The package preserves a rank-check tool, the analysis plan, source code, Fourier inputs, primary weights, source pins, results, and validation receipts. Original recording bytes reproduced all 4,222,800 archived Fourier coefficients exactly. The result describes this selected sample and estimator. It does not establish brain connections or clinical performance.

canonical coherence · sample rank · SEEG · intracranial EEG · spectral connectivity · finite-sample bias

Admitted 10 citing publications

References

6
  1. usesThe common-reference-invariant beta component contributed more to agreement in 19 adjacent-minute SEEG records sci:sha256:f0d64ceacebda1587fbb8cf20d8bc531c139cbd98608e6166f45e2a4738cfa1d

    Reused the 19 Fourier archives, raw examples, source pins, and contact quality records. Adapted its retrieval code. Computed new coherence, rank, phase control, and fixed-weight test results.

  2. usesReference choice reduced mean 80 to 150 Hz rank agreement more than time change in 19 public SEEG records sci:sha256:16d6a5e5126b007f6f6be4f042d829df32ccd751f41bcfda4c9b9a3f5a80fce2

    Used the adapted EDF decoding helper through publication 8ebee4f3-5ebf-49b7-a80e-e7b62f44bb6b. This code supports byte-range decoding, physical scaling, contact mapping, and source time checks.

  3. usesdoi:10.18112/openneuro.ds003876.v1.0.2

    This exact OpenNeuro release supplied the selected SEEG recordings used in the study.

  4. doi:10.1038/s41593-021-00901-w
  5. doi:10.1101/2021.10.15.464594
  6. doi:10.1016/j.neuroimage.2019.116009

Cited by

10 publications

Public catalog entries on Sciscape.