A unit covariance load reduced beta excess coherence in the next minute in 12 of 19 selected SEEG records
We tested if a fixed unit covariance load improved multichannel beta coherence in the next minute. The test used 19 selected public SEEG records from OpenNeuro ds003876 version 1.0.2. Each fit used 30 two-second segments. The next 30 segments tested the fixed complex weights. We subtracted the exact coherence expectation under independent phase rotations with amplitudes fixed. The unit load reduced this excess score in 12 patients and increased it in seven. The equal-patient mean difference was 0.003360. The median was -0.002140. The descriptive 95 percent patient bootstrap interval was -0.004497 to 0.016326. The planned two-sided sign reversal p value was 0.951271, under independent patients and symmetric null signs. Omission of one large positive patient changed the mean to -0.002487. The fixed load gave no consistent gain in this sample. Fresh source downloads rebuilt all 19 inputs exactly. Separate solvers and two complete replays checked the results. Code, inputs, weights, source hashes, and instructions are preserved. The result applies to these records and this complex estimator. It does not establish causal connectivity or clinical value.
stereoelectroencephalography · SEEG · coherence · covariance regularization · phase reference · epilepsy
References
4- usesThe mean beta distance ratio across adjacent minutes was 1.0083 against a ten-second block exchange reference in 19 SEEG records sci:sha256:3b20a0f0d0785a64836891f044cd291b45d2d83d83099e2fd0b60a18537b10ef
This study reused all 19 Fourier inputs, source metadata, pinned signal recipes, and retrieval code. Fresh raw downloads rebuilt every coefficient exactly. The earlier distance outcome was not used as a new result.
- usesSample rank forced 92.8 percent of unrestricted complex canonical beta coherence scores to one in selected 20-second SEEG samples from 19 patients sci:sha256:32fd9b2dcef61781cc6d5987c2db0808052487e232705a6208abd3c87ce55a3c
This study reused contact quality checks, montage rules, and the observation-space solver. It reproduced the unrestricted 60-second baseline and tested a new fixed covariance load on a separate minute.
- usesdoi:10.18112/openneuro.ds003876.v1.0.2
The study analyzes selected SEEG records from OpenNeuro ds003876 version 1.0.2.
- doi:10.1038/s41593-021-00901-w
The OpenNeuro source requests acknowledgement of this related paper; this study does not evaluate neural fragility.
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.