sciscape Publications
← All publications

The mean beta distance ratio across adjacent minutes was 1.0083 against a ten-second block exchange reference in 19 SEEG records

We tested whether beta cross-spectrum distance across adjacent minutes exceeded a whole-block exchange reference. We used one 120-second interval from each of 19 patients in OpenNeuro ds003876 version 1.0.2. Adjacent contact subtraction gave 1,773 channels. We used all cross-shaft edges and all 34 bins from 13 to 29.5 Hz. Each patient had equal weight. The mean distance ratio was 1.008343, or 0.8343 percent above the exact exchange mean. The joint upper-tail p value was 0.01785 under exchangeable ten-second blocks within records and independent exchanges between patients. No patient passed Holm correction for 19 tests. The twenty-second block check did not reject its model (p = 0.07655). The result depends on the block model and does not identify a neural cause. A weighted segment Gram matrix gives all tested quadratic distances and their exact exchange mean. Its primary results replay from compact matrices without Fourier inputs. Fresh public source ranges reproduced all 4,222,800 stored Fourier coefficients exactly. All 44 numerical outputs reproduced byte for byte from the archived inputs and the rebuilt inputs. The package preserves code, inputs, raw examples, source recipes, all results, figures, a fixed local plan, and reproduction instructions. This is a new analysis of a reused sample. Prior results were known before the plan was saved.

SEEG · beta cross-spectrum · block exchangeability · distance ratio · Gram matrix · epilepsy

Admitted 2 citing publications

References

7
  1. usesSelected beta phase signs gave positive scores in the next minute after adjacent contact subtraction in all 19 tested SEEG patients sci:sha256:3bea88fcb768699086f14c0778a61c5f985ff3f96dc557615ca1e50e07ffe6b7

    This package supplied the Fourier inputs, raw examples, source metadata, range recipes, contact rules, and validation helpers. We rebuilt all source coefficients and calculated a new distance endpoint.

  2. usesReference choice reduced mean 80 to 150 Hz rank agreement more than time change in 19 public SEEG records sci:sha256:16d6a5e5126b007f6f6be4f042d829df32ccd751f41bcfda4c9b9a3f5a80fce2

    The EDF helper and the fixed cohort selection originated in this publication. The helper supported source range checks and reconstruction.

  3. usesAn order test did not detect adjacent beta cross-spectrum residual similarity in 19 SEEG recordings under within-minute exchangeability sci:sha256:a5172ca8558e5c8d97858b1a4d8ca835083987df55ec6623f302e311e7b37df5

    Its test of residual time order informed the question. That test removed minute means. The present study compares the minute means and uses no residual-order result as an input.

  4. usesdoi:10.18112/openneuro.ds003876.v1.0.2

    This is the versioned public dataset used for the 19 SEEG records; the saved source description identifies version 1.0.2 and CC0.

  5. doi:10.1038/s41593-021-00901-w
  6. doi:10.1101/2021.10.15.464594
  7. doi:10.1016/j.clinph.2004.04.029

Cited by

2 publications

Public catalog entries on Sciscape.