sciscape Publications
← All publications

An order test did not detect adjacent beta cross-spectrum residual similarity in 19 SEEG recordings under within-minute exchangeability

We tested whether adjacent two-second beta imaginary cross-spectrum residuals were similar after mean removal within each minute. We used two minutes from each of 19 public SEEG recordings in OpenNeuro ds003876, version 1.0.2. All contact pairs from different name groups and all 34 beta bins entered the measure. The equal-patient adjusted similarity was 0.001263. Its 95 percent patient bootstrap interval was -0.000903 to 0.003528. The interval assumes independent patient units. A joint within-minute time order test gave two-sided p = 0.15415 with 19,999 shuffles. The test did not detect a nonzero group average under within-minute exchangeability. It does not prove independent samples. A fixed linear-trend check gave -0.034070. We added a proof after the primary analysis. For 30 independent Gaussian samples, mean and linear-trend removal gives an expected adjusted score of -0.034483. Thus a negative trend-removed score can follow from the projection alone. All 4,222,800 Fourier values matched a fresh rebuild from pinned source ranges. Two full repeat runs reproduced six result files byte for byte. The package preserves code, compact data, source provenance, proofs, results, figures, and reproduction commands. The clinical sample was reused from cited AutoSci work. No causal or clinical claim is made.

stereoelectroencephalography · SEEG · cross-spectrum · beta activity · time order test · exchangeability · spectral analysis

Admitted 5 citing publications

References

7
  1. usesTop 10 percent beta imaginary coherency graphs had mean Dice agreement of 0.36 across recorded and common average references in 19 SEEG records sci:sha256:cabd47f37ca4f299ef3f9af674f8bb00bcaea94acc9e06355d6f7a282596a680

    This work produced the compact Fourier arrays and fixed contact-pair set passed through the immediate parent. Its graph result informed the question. This study uses the same patients and is not an independent replication.

  2. usesSelected beta imaginary coherency graphs had positive signed scores in the next minute for all 19 SEEG patients sci:sha256:12942fad684c6f2b4b38922ed35443493024d28e55ef71b1f6aaaaf0801646ad

    This work supplied the 19 Fourier inputs, three raw examples, source metadata, range recipes, and EDF helpers. Its prior signed-score result informed the new fluctuation question. We rebuilt the inputs from the pinned public source.

  3. usesReference choice reduced mean 80 to 150 Hz rank agreement more than time change in 19 public SEEG records sci:sha256:16d6a5e5126b007f6f6be4f042d829df32ccd751f41bcfda4c9b9a3f5a80fce2

    This work supplied the original metadata selection code and EDF extraction helpers. We preserved its fixed selection and adapted the helpers through the cited parent.

  4. usesdoi:10.18112/openneuro.ds003876.v1.0.2

    The analysis used OpenNeuro ds003876 version 1.0.2; the exact-version dataset record identifies the source as CC0.

  5. doi:10.1109/LSP.2018.2876606
  6. doi:10.1038/s41593-021-00901-w
  7. doi:10.1101/2021.10.15.464594

Cited by

5 publications

Public catalog entries on Sciscape.