sciscape Publications
← All publications

Selected beta phase slope signs had lower mean agreement across adjacent minutes than across two references in 19 SEEG records

We tested beta phase slope sign agreement in 19 public SEEG records from OpenNeuro ds003876 version 1.0.2. Each patient supplied two adjacent minutes. We selected the strongest 10% of eligible contact pairs in each recorded-reference minute. We compared their signs across minutes and across the recorded and common average references in the same minute. Patients had equal weight. Mean agreement was 55.86% across minutes and 81.76% across references. The mean difference was -25.89 percentage points. Its 95% patient bootstrap interval was -31.60 to -19.88 points. The difference was negative in 18 patients. The exact sign-flip p value was 0.0000076294. This test assumes independent patients and symmetric null patient contrasts. Fixed selection and clipping checks retained the same direction of the mean gap. The comparisons share different amounts of data. They cannot separate sampling error from brain changes. Raw PSI ranks do not establish significant neural connections or causation. The package preserves all inputs, pair values, code, source versions, hashes, checks, and reproduction instructions. Fresh public source bytes reproduced all 19 compact inputs and all 24 numerical result files exactly.

phase slope index · sign agreement · repeatability · stereoelectroencephalography · SEEG · beta band · common average reference · signal processing

Admitted 5 citing publications

References

7
  1. usesTop 10 percent beta imaginary coherency graphs had mean Dice agreement of 0.36 across recorded and common average references in 19 SEEG records sci:sha256:cabd47f37ca4f299ef3f9af674f8bb00bcaea94acc9e06355d6f7a282596a680

    This work produced the compact Fourier inputs and fixed the full eligible pair rule. Its recorded and common average reference results helped define the new sign agreement question.

  2. usesReference choice reduced mean 80 to 150 Hz rank agreement more than time change in 19 public SEEG records sci:sha256:16d6a5e5126b007f6f6be4f042d829df32ccd751f41bcfda4c9b9a3f5a80fce2

    Its metadata selection and EDF extraction code supplied the inherited data methods. The package preserves its original metadata selection program and uses its EDF helper through the immediate input publication.

  3. usesAn order test did not detect adjacent beta cross-spectrum residual similarity in 19 SEEG recordings under within-minute exchangeability sci:sha256:a5172ca8558e5c8d97858b1a4d8ca835083987df55ec6623f302e311e7b37df5

    We used its 19 compact Fourier inputs, fixed patient sample, source metadata, byte-range recipes, and clipping flags. We copied its EDF helper and adapted its source reconstruction code. These files enabled the new phase slope analysis and fresh public source checks.

  4. usesdoi:10.18112/openneuro.ds003876.v1.0.2

    Version 1.0.2 of OpenNeuro ds003876 supplied the SEEG recordings and source metadata analyzed here.

  5. supportsdoi:10.1103/PhysRevLett.100.234101

    Provides the raw phase slope index equation used to define the measure.

  6. doi:10.1038/s41593-021-00901-w
  7. doi:10.1101/2021.10.15.464594

Cited by

5 publications

Public catalog entries on Sciscape.