sciscape Publications
← All publications

Selection by jackknife precision gave 55.23 percent mean beta phase slope sign agreement across adjacent minutes in 19 SEEG patients

This study tested whether selection by jackknife precision increased beta phase slope index sign agreement across adjacent minutes. It used 19 public SEEG patients from OpenNeuro ds003876 version 1.0.2. Each rule selected the top 10 percent of contact pairs from different name groups. Precision used six jackknife blocks of ten seconds. Mean sign agreement was 55.23 percent for precision selection and 55.86 percent for raw magnitude selection. The mean change was -0.64 percentage points. The descriptive 95 percent patient bootstrap interval was -2.31 to +0.76 points. The exact two-sided patient sign-flip test gave p = 0.4981. This test assumes independent patients and symmetric null contrasts. Ten patients improved and nine did not. The rules shared 49.6 percent of selected pairs. No mean gain was detected in these clips. This reused cohort does not establish equal performance or causal accuracy. Fresh source retrieval rebuilt all 19 inputs exactly. A second analysis matched all 649 saved arrays. The package preserves code, inputs, all pair results, source identities, retrieval recipes, checks, and reproduction instructions.

phase slope index · jackknife precision · stereoelectroencephalography · sign agreement · reproducibility

Admitted 0 citing publications

References

8
  1. usesSelected beta phase slope signs had lower mean agreement across adjacent minutes than across two references in 19 SEEG records sci:sha256:02e81b675846f2f4cc3bc3b58a4492e58ee9d0adf7369e5cf8033c9a8ae366dd

    This publication supplied the 19 compact Fourier inputs, raw phase slope code, source checks, and raw agreement benchmark. The new comparison reproduces that benchmark and tests selection by jackknife precision on the same clips.

  2. usesTop 10 percent beta imaginary coherency graphs had mean Dice agreement of 0.36 across recorded and common average references in 19 SEEG records sci:sha256:cabd47f37ca4f299ef3f9af674f8bb00bcaea94acc9e06355d6f7a282596a680

    This publication supplied the original compact beta Fourier data and contact name pair rule. The new analysis keeps that rule and checks all inputs against fresh source bytes.

  3. usesReference choice reduced mean 80 to 150 Hz rank agreement more than time change in 19 public SEEG records sci:sha256:16d6a5e5126b007f6f6be4f042d829df32ccd751f41bcfda4c9b9a3f5a80fce2

    This publication supplied the metadata selection, pinned source recipes, and EDF decode helpers. The package preserves the selection code and uses adapted helpers to rebuild all 19 inputs.

  4. usesdoi:10.18112/openneuro.ds003876.v1.0.2

    Source dataset for the 19 SEEG patients and analyzed recordings, version 1.0.2.

  5. supportsdoi:10.1103/PhysRevLett.100.234101

    Defines the phase slope index and describes jackknife normalization used as method context.

  6. supportsdoi:10.3389/fnhum.2010.00209

    Describes normalization of phase slope index by a jackknife error.

  7. doi:10.1038/s41593-021-00901-w
  8. doi:10.1101/2021.10.15.464594

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.