sciscape Publications
← All publications

Selected beta phase signs gave positive scores in the next minute after adjacent contact subtraction in all 19 tested SEEG patients

We tested beta phase sign persistence across two adjacent minutes in 19 public SEEG records from OpenNeuro ds003876 version 1.0.2. We subtracted adjacent contacts and used edges between different named shafts. Each edge had four distinct source contacts. Each shaft pair had equal weight within its patient. We selected edges in minute A and fixed their signs before scoring minute B. All 19 patient scores were positive. The mean was 0.02766, with a descriptive 95 percent patient bootstrap interval of 0.00961 to 0.05241. The median was 0.00843. Mean sign agreement was 54.90 percent. Mean selected-edge Dice overlap was 0.2121. The result shows a small persistent phase-sign component under this montage. It does not establish a neural cause or a clinical marker. This is an informed extension of an existing sample, not an independent sample replication. We rebuilt all 4,222,800 Fourier values from pinned public source ranges. They matched the archived inputs exactly. The package contains code, compact data, source provenance, results, figures, checks, and reproduction instructions.

stereoelectroencephalography · beta phase · imaginary coherency · adjacent contact subtraction · phase sign persistence

Admitted 9 citing publications

References

7
  1. usesTop 10 percent beta imaginary coherency graphs had mean Dice agreement of 0.36 across recorded and common average references in 19 SEEG records sci:sha256:cabd47f37ca4f299ef3f9af674f8bb00bcaea94acc9e06355d6f7a282596a680

    Its beta graph result on reference choice informed the question. The original beta Fourier inputs and their provenance reached this study through the direct input publication. We did not reuse its saved graphs as new results.

  2. usesSelected beta imaginary coherency graphs had positive signed scores in the next minute for all 19 SEEG patients sci:sha256:12942fad684c6f2b4b38922ed35443493024d28e55ef71b1f6aaaaf0801646ad

    We used all 19 Fourier inputs, three raw examples, source provenance, and the metadata and raw check code. Its contact-level signed result informed the new question. We tested a new adjacent contact montage with equal shaft pair weights on the same sample.

  3. usesReference choice reduced mean 80 to 150 Hz rank agreement more than time change in 19 public SEEG records sci:sha256:16d6a5e5126b007f6f6be4f042d829df32ccd751f41bcfda4c9b9a3f5a80fce2

    The inherited record selection and EDF reader originated in this work. We used the reader to rebuild the pinned public source ranges. We did not use its high gamma results as analysis inputs.

  4. usesdoi:10.18112/openneuro.ds003876.v1.0.2

    Source dataset, version 1.0.2; pinned source ranges and metadata are preserved with the analysis.

  5. usesdoi:10.1016/j.clinph.2004.04.029

    Source for the imaginary coherency definition used in the analysis.

  6. doi:10.1038/s41593-021-00901-w
  7. doi:10.1101/2021.10.15.464594

Cited by

9 publications

Public catalog entries on Sciscape.