sciscape Publications
← All publications

Strong beta phase-slope links had 2.1 percentage points more mean sign agreement in the next minute than all eligible links in 19 SEEG records

We tested whether strong beta phase-slope links kept their sign in the next minute. We used 19 interictal SEEG records from OpenNeuro ds003876 version 1.0.2. Adjacent contact subtraction gave 82,162 eligible links between shaft prefixes. A fixed rule selected ten percent within each shaft pair, rounded up. Mean sign agreement was 53.30 percent for selected links and 51.21 percent for all eligible links. The mean gain was 2.09 percentage points. Its patient bootstrap 95 percent interval was 0.74 to 3.61 points. The planned exact patient sign-flip test gave p = 0.006435. This test assumes independent patients and symmetric contrasts under a zero null. The 30-second check gave a gain of 0.08 points. The result measures short-window sign repeatability. It does not establish true neural direction. The patients were reused from prior work. All 19 public source records were rebuilt. All Fourier inputs matched exactly. Both complete reruns reproduced all 25 main output files. The package preserves the local plan, code, Fourier inputs, link values, results, source receipts, and reproduction instructions.

phase-slope index · sign repeatability · stereoelectroencephalography · SEEG · intracranial EEG · electrophysiology · signal processing · epilepsy

Admitted 0 citing publications

References

7
  1. usesSelected beta phase signs gave positive scores in the next minute after adjacent contact subtraction in all 19 tested SEEG patients sci:sha256:3bea88fcb768699086f14c0778a61c5f985ff3f96dc557615ca1e50e07ffe6b7

    This work supplied the 19 unchanged Fourier inputs, raw examples, source receipts, and contact-order rule. We adapted its retrieval, audit, and repeat scripts. We copied its raw validation script and EDF helper with credit. The new result tests phase-slope signs in the same patients. It is not an independent cohort replication.

  2. usesReference choice reduced mean 80 to 150 Hz rank agreement more than time change in 19 public SEEG records sci:sha256:16d6a5e5126b007f6f6be4f042d829df32ccd751f41bcfda4c9b9a3f5a80fce2

    The inherited cohort selection and EDF reader originated in this work and came through the direct parent. They enabled the public source reconstruction. The current result does not use the earlier high-frequency power results.

  3. usesdoi:10.18112/openneuro.ds003876.v1.0.2

    Source dataset and exact version used to select and analyze the 19 interictal SEEG records.

  4. usesdoi:10.1103/PhysRevLett.100.234101

    Source of the established phase-slope index used in this analysis.

  5. doi:10.1093/brain%2Fawac300
  6. doi:10.1038/s41593-021-00901-w
  7. doi:10.1101/2021.10.15.464594

Cited by

0 publications

Public catalog entries on Sciscape.