Full five-pulse subtraction increased mean 70–110 Hz threshold crossings at 100–500 ms after stimulation in eight SEEG patients with fixed raw thresholds

We tested fixed waveform subtraction in public SEEG data from OpenNeuro ds004696 version 1.0.1. The sample had eight patients, 86 sites, and 886 recording-pair instances. Five early pulses fitted each template; five later pulses supplied test data. Four short blocks covered 100 to 500 ms after each pulse in the nominal 70 to 110 Hz band. At a fixed threshold from 20 early raw before-pulse powers, full subtraction changed after-pulse crossings by 5.60 percentage points (95% patient interval 4.81 to 6.43). The matched before-pulse change was 4.89 points (3.81 to 5.74). The primary after-minus-before contrast was 0.71 points (-0.57 to 2.24); it did not show a clear mean reduction. The exact patient sign-flip probability was 0.429688. Signals had no intended-command labels; crossings are not proven false commands. Activity in the first 100 ms and task decoding were not tested. The package retains compact inputs, source hashes, results, figures, and reproduction instructions. GPL analysis code is omitted; two proofs explain small-sample thresholds and template-noise power under stated independence assumptions.

stereoelectroencephalography · brain-computer interface · stimulation artifact · high-gamma activity · waveform subtraction · threshold crossings · calibration · signal processing

Admitted 0 citing publications

References

6
  1. usesThe fixed template power ratio rose by 0.16 dB from before to 100 to 500 ms after pulses at 2 to 30 Hz in eight SEEG patients sci:sha256:d4baefad8402adfc85c4fd0f3c1ac9011e905eb300617ca36a6261180bc8bd6d

    Its fixed-template result supplied related evidence about calibration noise in a different STReEF sample at 2–30 Hz. It helped define the question. This study uses HAPwave data and tests 70–110 Hz threshold crossings. No STReEF data were used.

  2. usesPaired after-to-before SEEG variance ratios were 1.51 times as large at 4–30 Hz as at 70–110 Hz in eight epilepsy patients sci:sha256:f8e2e43e31aa8c3dc30e483a7b3326a27352569537f8abef6009a2ecd5c5546a

    We used its fixed tables for 86 stimulation sites and 886 eligible recording-pair instances in eight patients. We also used its source pins, source metadata, and retrieval code. We computed new short-block Fourier inputs and held-out threshold results from all eight complete native derivatives. This is the same cohort.

  3. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    Source voltage data and BIDS metadata for the exact analyzed OpenNeuro release.

  4. doi:10.1523/JNEUROSCI.2201-22.2023
  5. doi:10.1038/s41467-026-75265-5
  6. doi:10.1088/1741-2552%2Fab7a4f