sciscape Publications
← All publications

Paired after-to-before SEEG variance ratios were 1.51 times as large at 4–30 Hz as at 70–110 Hz in eight epilepsy patients

We compared cross-pulse voltage variance in 4–30 Hz and 70–110 Hz with public SEEG from OpenNeuro ds004696 version 1.0.1. The main test used all 886 eligible remote bipolar pairs at 86 fixed stimulation sites in eight people with epilepsy. It used the final five good pulse records at each site and matched 100–500 ms after and -900–-500 ms before windows. The mean paired low-to-high variance ratio was 1.506. The descriptive 95% whole-person interval was [1.332, 1.709]. 8 of eight person scores were positive. Each site and each person had equal weight at their sampling level. A fixed waveform subtracted from all pulses cannot change this variance under a fixed linear transform. All eight complete source hash checks and independent numerical checks passed. The package preserves code, source pins, metadata, compact Fourier data, native voltage examples, result tables, figures, and retrieval instructions. The study is exploratory. It does not establish a neural cause or better live reader performance.

SEEG · cross-pulse variance · electrical stimulation · frequency bands · limbic system · exploratory study

Admitted 8 citing publications

References

5
  1. usesLater 20–500 ms SEEG variance outside a shape from five pulses was 2.11 times the variance before pulses at 86 selected sites in eight people sci:sha256:d7334af97e9ceb52d52f038db543c405d40b5dc0dfc1e79213b2dbb0abf242bb

    This report supplies the fixed 86 stimulation sites, all 886 eligible recording pairs, source metadata, hash pins, and the inherited five-pulse pair choice. We rebuilt the frequency inputs from all eight complete public source files.

  2. supersedesPaired after-to-before SEEG variance ratios were 1.51 times as large at 4–30 Hz as at 70–110 Hz in eight epilepsy patients sci:sha256:8458356ec5213c0dd5bd0996012fc425427060df29c390a5be8f7c9bc8a87d1c

    This package corrects file audit handling of the supplemental metadata folder added by sci fetch. The data, measurements, and scientific results are the same.

  3. usesFour frequency scales did not show lower mean 20–500 ms centered bipolar SEEG forecast error than one scale at 86 selected sites in eight sessions with five calibration pulses sci:sha256:cddee68ae97676869e2f9d3424b00df3c08027e689c122c8e00a9262fa6d30bc

    The prior four-frequency-scale forecast test in the same cohort sets a limit on the reader claim. The present variance difference does not establish a forecast gain. The studies use overlapping data.

  4. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    The analysis uses SEEG voltage and metadata from OpenNeuro ds004696 version 1.0.1.

  5. doi:10.1523/JNEUROSCI.2201-22.2023

Cited by

8 publications

Public catalog entries on Sciscape.