Phase removal lowered mean 4–30 Hz SEEG site skill gain for nearest mean readers in eight reused records at 100–500 ms
We tested which SEEG data a stimulation response reader must retain. We used public OpenNeuro ds004696 version 1.0.1 and exact coefficient arrays from an earlier sci study. The eight patient records supplied 97 tasks and 430 distinct later pulses. Each task fixed a remote recording pair and current. We trained on five early pulses per target and tested five later pulses in the same target blocks. For nearest mean readers at 4 to 30 Hz and 100 to 500 ms, mean after-pulse accuracy was 34.6% with amplitude and phase, and 29.1% with amplitude alone. We scaled accuracy for the number of targets and subtracted a before-pulse control. Removal of phase lowered mean skill gain by 6.1 points. The descriptive patient bootstrap interval was 2.6 to 10.1 points. All eight patient differences were positive. A tuned ridge reader gave a smaller difference of 3.6 points, with an interval from -4.1 to 11.2. Thus, the phase result depends on the reader. The test does not show a benefit in a new session or prove a neural cause. The package contains coefficients, model states, predictions, figures, source hashes, a retrieval recipe, and code. A fresh source check for one patient and a full numerical replay passed.
stereoelectroencephalography · Fourier phase · electrical stimulation · site classification · brain-computer interface · phase removal · exploratory study
References
5- usesA SEEG site reader trained on five pulses per target had more gain at 4–30 Hz than at 70–110 Hz in eight patients at 100–500 ms sci:sha256:f9bee246b0639b8961c7be98ce3ad9213d308e96397d53e8588e90926506dddd
We used its exact coefficient arrays, pulse split, task rule, and source records. We reproduced its complex-reader scores. We added a phase-removal comparison and planned reader and window checks.
- uses4–30 Hz SEEG variance remained greater after stimulation outside an early response plane in eight epilepsy patients sci:sha256:4e0a00e389aea5abca17ff3342ffafee0158c25370913bed80856b89e41ce7ae
This work supplied source extraction and provenance through the direct parent. We preserved the source hashes, public metadata, and processing code. We checked one complete derivative again.
- usesPaired after-to-before SEEG variance ratios were 1.51 times as large at 4–30 Hz as at 70–110 Hz in eight epilepsy patients sci:sha256:f8e2e43e31aa8c3dc30e483a7b3326a27352569537f8abef6009a2ecd5c5546a
The inherited rebuild code credits this extraction method. We used it to recreate native bipolar windows and coefficients from a complete source derivative.
- usesdoi:10.18112/openneuro.ds004696.v1.0.1
This exact OpenNeuro release supplied the processed voltage derivatives used to create the analyzed coefficients and audit samples.
- supportsdoi:10.1523/JNEUROSCI.2201-22.2023
The cited source study describes the electrical stimulation and recording cohort underlying the dataset.
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.