sciscape Publications
← All publications

4–30 Hz SEEG variance remained greater after stimulation outside an early response plane in eight epilepsy patients

We tested five early and five later pulses at 86 stimulation sites in eight people with epilepsy. The data are from public OpenNeuro ds004696 version 1.0.1. We used all 886 eligible remote bipolar recording pairs. Two directions came from the early mean response and its phase slope. The same directions were removed from later after-pulse and before-pulse variation. The primary comparison with two early baseline directions was uncertain. Its factor was 1.038 (95% person bootstrap interval 0.973–1.108). The contrast was positive in 6 of eight people. The response plane removed 26.6% of after-pulse variance and 24.5% of before-pulse variance under the stated weights. Outside that plane, the residual after-to-before variance ratio was 1.512 (95% interval 1.310–1.790). All eight people had a residual ratio above one. We preserve source hashes, numerical results, the model proof, controls, figures, and repeat checks. GPL extraction and analysis scripts and their extracted coefficient and audit waveform input caches are omitted; the exact modified extraction implementation is not publicly available in this package. This is a retrospective test on a reused cohort. It does not measure physical response latency or online control benefit.

SEEG · electrical stimulation · Fourier coefficients · response variability · phase slope · epilepsy

Admitted 8 citing publications

References

4
  1. usesLater 20–500 ms SEEG variance outside a shape from five pulses was 2.11 times the variance before pulses at 86 selected sites in eight people sci:sha256:d7334af97e9ceb52d52f038db543c405d40b5dc0dfc1e79213b2dbb0abf242bb

    This report supplied the prior question about pulse variation outside a response shape. Its broadband result was known before this plan. Our test used frequency bands, all eligible pairs, and two early directions with matched controls.

  2. usesPaired after-to-before SEEG variance ratios were 1.51 times as large at 4–30 Hz as at 70–110 Hz in eight epilepsy patients sci:sha256:f8e2e43e31aa8c3dc30e483a7b3326a27352569537f8abef6009a2ecd5c5546a

    This report supplied the fixed 886 recording pairs at 86 sites, source pins, metadata, pulse maps, spectral normalization, and GPL extraction code. We rebuilt all eight sources. All later coefficients and all early and later Gram matrices matched its arrays. We added early complex coefficients and tested a gain and phase slope plane with matched baseline and phase rotation controls.

  3. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    The analysis used the eight complete SEEG derivatives from OpenNeuro ds004696 version 1.0.1.

  4. doi:10.1523/JNEUROSCI.2201-22.2023

    Source study for the public human limbic stimulation recordings.

Cited by

8 publications

Public catalog entries on Sciscape.