A five-pulse SEEG test did not show a clear increase in the 4–30 Hz persistence gap after stimulation in eight people
We tested whether power that repeated within five pulses persisted across a later five-pulse group. We used public SEEG data from eight people with epilepsy, with 86 stimulation sites and 886 bipolar readout instances. The main score was within-group power minus across-group power, divided by total power. We compared 100–500 ms after stimulation with a matched before-pulse window. The 4–30 Hz gap changed by 0.19 percentage points. Its descriptive 95% person bootstrap interval was −1.26 to 1.83 points. The exact person sign-flip reference was 0.8516. The main result was uncertain and does not establish equivalence. Across-group low-band power rose above the before-pulse control. Secondary 70–110 Hz estimates varied with the taper and time window. The package preserves three figures, compact data, a proof with explicit error assumptions, source metadata, and numerical replay receipts. All eight complete source files passed full hash checks and reproduced the compact arrays. GPL analysis and extraction code is omitted; the package does not enable a code replay.
stereoelectroencephalography · SEEG · electrical stimulation · evoked responses · signal power · within-group power · persistence gap · Fourier analysis · epilepsy · reproducibility
References
6- usesFive-pulse estimates showed a greater mean 100 to 500 ms rise in repeatable power fraction at 2 to 30 Hz than at 70 to 150 Hz in eight STReEF SEEG runs sci:sha256:552984215d5744e6e94b5e864c21d391db78acd541661c7f6652caab5f35404d
This report supplied the prior five-pulse repeatable-power question and within-group estimator. We compare within-group and across-group power in a different public dataset with a before-pulse control.
- usesThe fixed template power ratio rose by 0.16 dB from before to 100 to 500 ms after pulses at 2 to 30 Hz in eight SEEG patients sci:sha256:d4baefad8402adfc85c4fd0f3c1ac9011e905eb300617ca36a6261180bc8bd6d
This report supplied the corrected group mean difference identity. We use the same mathematical idea and state its error assumptions. The new contribution is the tested data comparison, not a new identity.
- uses4–30 Hz SEEG variance remained greater after stimulation outside an early response plane in eight epilepsy patients sci:sha256:4e0a00e389aea5abca17ff3342ffafee0158c25370913bed80856b89e41ce7ae
This parent supplied all first-five and last-five compact coefficients, fixed readout selection, pulse maps, original metadata, source pins, and extraction code. We verified its inputs and rebuilt all arrays from eight complete source derivatives.
- usesPaired after-to-before SEEG variance ratios were 1.51 times as large at 4–30 Hz as at 70–110 Hz in eight epilepsy patients sci:sha256:f8e2e43e31aa8c3dc30e483a7b3326a27352569537f8abef6009a2ecd5c5546a
This spectral parent supplied the inherited Fourier normalization and range retrieval recipe. The present code retains its attribution and license.
- usesdoi:10.18112/openneuro.ds004696.v1.0.1
The analysis uses processed voltage derivatives from OpenNeuro ds004696 version 1.0.1.
- doi:10.1523/JNEUROSCI.2201-22.2023
Source study for the ds004696 human limbic single-pulse response data analyzed here.
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.