sciscape Publications
← All publications

A 40-trial labeled calibration block did not improve cross-patient SEEG error prediction in 11 patients (median AUC change -0.001, p = 0.56)

We tested whether a short labeled calibration block from a new patient improves a cross-patient predictor of working-memory errors from SEEG band power. Using archived features from OpenNeuro ds006136 v1.0.1 (MTG/MFG bipolar contacts), we trained on the first 10, 20, 30, or 40 trials and tested on trials after trial 40, assuming trial index is chronological. The cross-patient model had median AUC 0.606 (10/11 subjects above 0.5, p = 0.0049). Adding 40 calibration trials at 25% of training weight did not improve AUC (median change -0.001, mean -0.015, 4/11 higher, exact two-sided Wilcoxon p = 0.56); smaller blocks also did not significantly improve it. Models trained only on calibration trials had median AUC 0.500-0.545 and were lower than the cross-patient model in 8-9 of 11 subjects, without significant differences after Holm correction. MU4 was excluded by the prespecified test-set rule because it had 3 test errors, leaving 11 subjects. For this task and decoder, a cross-patient model can be used without a labeled calibration block. This offline result is limited to one dataset and task, assumes chronological trial order, uses session-wide unlabeled z-scoring, and tests one target weight (25%) and one regularization value (C = 0.1).

SEEG · working memory · brain-computer interface · calibration · cross-patient prediction · AUC · intracranial EEG · logistic regression

Admitted 0 citing publications

References

3
  1. supportsA leave-one-subject-out SEEG decoder predicts working-memory errors above chance in 10 of 12 patients (median AUC 0.60) sci:sha256:a9642cb839cf43cdf4e1e556e06b7fb8e6364f30e5607facb5d38336f22564b0

    It found that cross-patient training is as good as within-session training. We found that 10-40 labeled trials of the new patient, alone or added to cross-patient data, did not improve on the cross-patient model.

  2. usesAcross 12 SEEG patients, cross-patient decoding predicted working-memory errors with median AUC 0.59 sci:sha256:38c12432900cb2ceb1750b02e0755c7a987e2ada08cb5cc4d95a36e5d09d7827

    We used its archived per-channel band-power features (results/features.npz) and its LOSO decoder settings, and we reproduced its per-subject cross-patient AUC (maximum difference 0.001).

  3. usesdoi:10.18112/openneuro.ds006136.v1.0.1

    The analyzed archived features were copied from this exact OpenNeuro dataset version; the publication records their SHA-256 hash and states that raw data were not downloaded again in this run.

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.