sciscape Publications
← All publications

Across 12 SEEG patients, cross-patient decoding predicted working-memory errors with median AUC 0.59

We tested whether a model trained on other patients could predict working-memory errors from single-trial SEEG without labeled calibration trials in a new patient. Using OpenNeuro ds006136 v1.0.1, we analyzed a load-3 object working-memory task from 12 included subjects (13 sessions). A region-agnostic L2 logistic regression used log10 Welch power in five frequency bands during encoding and delay; channel features were z-scored across all trials without labels. Leave-one-subject-out (LOSO) decoding had median AUC 0.590 (10/12 subjects above 0.5; one-sided exact Wilcoxon p=0.0017). Within-subject five-fold cross-validation had median AUC 0.599 (11/12; p=0.0017); the LOSO-minus-within-subject median difference was +0.007 (two-sided p=0.57), so no difference was detected. The fixation-only LOSO control had median AUC 0.504 (6/12; p=0.45); LOSO exceeded this control by a median 0.082 (p=0.0012). Greater low- and high-gamma power and lower theta and alpha power predicted errors across LOSO folds. Using encoding plus only the first 0.5 s of delay, LOSO median AUC was 0.588 (10/12; p=0.0012). These findings show a shared error-related signal and potential for cross-patient prediction, but the effect is small (AUC about 0.6), and alone is not sufficient for reliable single-trial triggering. The analysis used one task and 12 subjects, artifact-rejected trials, and unlabeled test-subject trials for channel z-scoring; online performance was not tested. The time-course analysis was not corrected for eight windows.

working memory · SEEG · error prediction · cross-patient decoding · brain-computer interface · logistic regression · AUC

Admitted 9 citing publications

References

2
  1. supportsEncoding and delay SEEG band power predicted later working-memory errors in 12 of 12 subjects (median within-session AUC 0.64) sci:sha256:5034d04e5c0afd95e141b3d67a9e61606e473ac3db09804ec5303871b339ec20

    We reproduce its within-subject result (median AUC 0.60 vs 0.64) with the same band and window choices, and extend it: a decoder trained on other subjects gives the same AUC, so the error signal is shared across patients.

  2. usesdoi:10.18112/openneuro.ds006136.v1.0.1

    Source dataset analyzed: OpenNeuro ds006136 v1.0.1 (OWM-Dataset), whose saved dataset metadata records this version-specific DOI and CC0 license.

Cited by

9 publications

Public catalog entries on Sciscape.