Adding six spectral features increased mean seizure onset label recall within a 10 percent contact budget in 31 SEEG patients

We tested small contact lists in public SEEG data from OpenNeuro ds004100, version 1.1.3. The test used 31 patients and 2,879 eligible contacts. Each test patient was absent from model training. The models trained on one recording and scored the other recording. At a budget of at most 10 percent of contacts, spectra plus contact number captured a mean 32.5 percent of seizure onset labels per patient. Contact number alone captured 20.9 percent. The mean increase was 11.5 percentage points. A 500-draw patient bootstrap refitted both models. Its approximate 95 percent interval for the increase was 3.8 to 18.5 percentage points. The spectral lists shared a mean 85.7 percent of contacts between two recordings. Four lists had no onset label in the primary test. The package includes spectra, metadata, raw retrieval records, code, all scores and lists, and independent checks. This is a new analysis of an existing hospital cohort. It does not establish surgical benefit or performance at another hospital.

stereo-EEG · seizure onset zone · spectral features · contact budget · label recall · patient-level evaluation · logistic regression

Admitted 1 citing publication

References

4
  1. usesSix CAR spectral features raised mean seizure onset label AUC beyond contact number. Fixed logistic tests excluded each of 31 SEEG patients. sci:sha256:aee5a470b0833c4f856b9a317fa6e6005828d574f583119a67ef17a72b7a7b3f

    This study uses the fixed six-feature model definition, cohort rules, parent contact table, and preserved source archive. It keeps the two recordings separate and tests label recall at fixed contact budgets.

  2. usesIn 30-second HUP SEEG samples, reference changes reduced mean 30–100 Hz slope rank agreement more than run changes sci:sha256:b9c7b4646dba303292f492835f91dbb8026d4f35fcce938519d1d3fa6bcbff63

    This study uses the original public SEEG spectra, source signal quality rules, reference equations, versioned raw byte-range records, and EDF code. Four raw ranges were checked with a separate decoder and manual Welch calculation.

  3. usesdoi:10.18112/openneuro.ds004100.v1.1.3

    The analysis uses SEEG recordings and clinical channel labels from OpenNeuro ds004100, version 1.1.3.