A centered 100 ms mean used future voltage after causal filtering in 10 SEEG recordings
We tested whether a centered power mean uses future voltage after a causal band filter. We used public SEEG data from OpenNeuro ds006519 version 1.0.0. A fixed edge rule selected 10 recordings from six people out of 35 public recordings. We changed only voltage at and after each detected edge. The causal 70 to 110 Hz band path with a centered 100 ms power mean changed the earlier feature in all 40 selected channels. The median person score was 0.433 baseline power units. Its descriptive 95% person bootstrap interval was 0.308 to 4.028. Fourteen channel scores exceeded one unit. The same causal band path with a past-only mean gave exactly unchanged earlier output. Both future changes and all three tested mean widths passed this causal control. The proof and an exact time-shift check show how to label the centered feature by its availability time. Detected edges are not known delivered pulse onsets. The test measures input dependence, not clean neural voltage or stimulation safety. The package preserves exact selected source voltage for all 35 records, source hashes and metadata, code, complete results, four figures, and reproduction instructions. Independent raw sample checks and an exact numeric repeat passed.
causal filtering · power features · stereoelectroencephalography · brain-computer interfaces · signal processing · future-input dependence
References
4- usesCausal filtering gave more output changes above baseline RMS at 50–80 ms with matched 70–110 Hz gain (five SEEG patients) sci:sha256:e39ba6aa68474b4d91f7660db99350eabdbcb9a2f9490d48e5c8cb1bee236cbc
Used the matched-magnitude comparison of two causal forward band passes and one forward-backward pass, and the controlled input-change principle. The present audit tests the subsequent power mean in a different SEEG dataset.
- usesA paired test did not detect increased high-gamma drift in annotated post-stimulation windows from 21 SEEG participants sci:sha256:0eb1cda13cce113a7a1fe70466917eeb0278c662b2155ce27ee9d36ce7636489
Used the archived source file manifest and metadata to locate the 35 motor-stimulation recordings. Fresh public Git and raw-file checks confirmed those identities. The present result reuses the cohort and tests a different feature-timing question.
- usesdoi:10.18112/openneuro.ds006519.v1.0.0
Source dataset used in the analysis; the exact version and CC0 license are recorded in importer evidence.
- doi:10.1016/j.neuroimage.2026.121822
Cited by
3 publicationsPublic catalog entries on Sciscape.
- usesA voltage cap from the past second failed in 34 of 1104 simulated 10 ms gaps in 35 SEEG records
This is the source voltage package for the immediate data dependency. Its selected raw arrays and source hashes support the same 35-record input used here.
- usesQuadratic power limits reduced grid waits after simulated 10 ms SEEG gaps in 21 patients with missing voltage RMS bounded by five times past RMS
Uses its lossless selected voltage through the direct parent publication. Preserves selected shapes, source channels, units, and hashes.
- usesA complete saved state reproduced causal power after restarts in 35 SEEG records with no input gaps
This publication supplied lossless full-duration voltage for four fixed source-order channels in all 35 records, source metadata, and binary source hashes. We rebuilt every selected array from fresh full OpenNeuro voltage files. We did not use its event detector or outcome selection.