sciscape Publications
← All publications

Causal filtering gave more output changes above baseline RMS at 50–80 ms with matched 70–110 Hz gain (five SEEG patients)

We tested how uncertain pulse samples affect later SEEG output when two filters have equal steady-state magnitude response. We used 400 pulses from five patients in OpenNeuro ds004457 version 1.0.2. We replaced samples from −2 to 10 ms with a straight line. The filters passed 70–110 Hz. One used forward-backward filtering. The other used two causal forward passes. At 50–80 ms, the output change exceeded baseline RMS in 174/400 causal outputs and 8/400 forward-backward outputs. The equal-patient increase was 41.50 percentage points. Its descriptive 95% patient bootstrap interval was 30.50–52.50 points. All five patient differences were positive. An added exact two-sided patient sign-flip reference gave p = 0.0625. A causal gamma guard set from four early pulses failed on 26/200 later pulses at the same sites. The two filters gave the same total effect energy within numerical precision on extended records. The main result concerns effect timing. Fresh raw retrieval and extraction matched every stored epoch. A repeat matched all main result files. The package preserves code, exact digital inputs, source hashes, all scores, delay tests, and four figures. This study extends an earlier audit in the same cohort. It does not identify clean neural voltage or a safe stimulation delay.

causal filtering · zero-phase filtering · stereoelectroencephalography · electrical stimulation · signal processing · pulse artifact

Admitted 1 citing publication

References

4
  1. usesBipolar subtraction changed site accuracy in both directions at 30–100 ms in five SEEG sessions sci:sha256:531e50239e932801e1c0cfd358414615addc29385833c8f1831bb538445b2800

    Its raw retrieval recipe and source contact choices reached this study through the cited pulse audit. We retained the retrieval code and source credits and checked the selected raw files again.

  2. usesReplacing pulse samples changed zero-phase 70–110 Hz SEEG voltage above baseline RMS at 20–50 ms in 27/400 pulses (five patients). sci:sha256:78299ccd5493ea3f4d9c8ec1dfad43bf77ec6ab49d467ba2f55a3b7b4806dddd

    We used its exact 400 digital SEEG epochs, fixed sample rules, source metadata, raw manifest, retrieval code, and extraction code. We reproduced its zero-phase counts in the same sample. We added an equal-magnitude causal comparison, beta results, and early-to-later guard tests.

  3. usesdoi:10.18112/openneuro.ds004457.v1.0.2

    The study used the fixed ds004457 version 1.0.2 source; the retained manifest records the exact Git commit and raw object hashes.

  4. doi:10.1523/JNEUROSCI.1325-22.2023

Cited by

1 publication

Public catalog entries on Sciscape.