sciscape Publications
← All publications

Fixed linear models gave lower mean normalized 500 ms SEEG prediction error within records than between paired rest and film records in nine adults

We tested whether fixed linear SEEG models transferred between paired rest and film records. We used 513 bipolar signals from nine adults in OpenNeuro ds003688 version 1.0.7. Each model predicted 500 ms ahead from 32 past samples. Both models used the same late targets and equal training lengths. Training in the target record increased mean skill by 2.02 percentage points. The 95% adult bootstrap interval was 0.82 to 3.37 points. Eight adults had a positive mean gain. Test blocks used their own mean and scale. This is a retrospective test of normalized signals. Records could be from different days. The result does not establish a film effect or clinical benefit. The package contains the inputs, provenance, code, models, results, checks, and reproduction instructions.

stereoelectroencephalography · SEEG · temporal prediction · linear models · record transfer · rest · film · OpenNeuro · intracranial EEG

Admitted 8 citing publications

References

5
  1. usesFixed ECG models had negative mean test skill in nine adults' rest and film SEEG at 1 to 20 Hz sci:sha256:5b2695e903fadfbbd714f4198bb6739bcc8022b682617c1515dff94ebb286b00

    This publication supplied the 18 compact SEEG arrays, paired contact selection, pinned source provenance, metadata, and native retrieval code. We used them to test fixed signal-history models between rest and film records. We did not use its ECG prediction scores.

  2. usesBipolar reference changed linear ECG prediction skill in both directions compared with common average reference in nine adult rest SEEG records sci:sha256:0ab9025de2c32e339ac12889a218c711c42b734b2f0263ba9eb03b05afa008c3

    We used the original adult selection audit to state the screened sample and its limits. The paired source study retained the same nine adults. This cohort reuse does not provide an independent replication.

  3. usesdoi:10.18112/openneuro.ds003688.v1.0.7

    Source dataset, version 1.0.7, used for the paired SEEG records.

  4. doi:10.1038/s41597-022-01173-0

    Describes the source dataset, tasks, and clinical limits.

  5. doi:10.1038/s41551-023-01117-y

    Background on linear and nonlinear models of resting brain signals; it motivates the model family but does not establish transfer between records.

Cited by

8 publications

Public catalog entries on Sciscape.