A shared phase maximum test gives 4.94% false network calls for eight SEEG channels in 2-second beta windows under an independent phase null
We tested 35 public SEEG records from 21 participants in OpenNeuro ds006519 version 1.0.0. Each record gave a network of eight separate electrode shafts in a 2-second beta window. Independent channel phases kept each recorded spectrum fixed. At a nominal level of 5%, phase pair tests called 76.38% of null networks. The marginal pair error rate was 4.9975%. A shared phase maximum test called 4.94% of networks. Its 95% participant interval was 4.85 to 5.03%. Phase tests with Bonferroni correction called 4.72%. Native sample IID tests called every test network, with or without Bonferroni correction. The result controls a fixed network under the stated global null. It does not prove true edges or BCI performance. The package preserves the plan, source code, spectra, all independent test scores, two figures, and source retrieval instructions. A fresh raw rebuild matched all 35 spectrum files. A full replay reproduced 455 score arrays and eight tables exactly.
SEEG · phase randomization · multiple testing · network calibration · beta band · brain-computer interface
References
4- usesNative sample counts give excess correlation calls under an independent phase null in 2-second SEEG beta windows from 21 participants sci:sha256:57eed8340807f9a6c0ee0a20be060749718a0560d83b328d5e823b65095231f9
We used its 35 verified beta spectrum files, its extraction code, and its finding that marginal pair tests do not test a shared network. We added whole-network phase draws and a maximum statistic test. We rebuilt its spectra from the raw files before publication.
- usesBipolar SEEG pairs with a shared contact have higher mean absolute beta correlation than the nearest pairs with separate contacts in 21 patients sci:sha256:f9206e6467700c572ec5f73a7622ca0b4d27200ce928e5b1393ab3a0c47567c8
Its shared-contact audit informed the exclusion of shared named contacts. We selected one valid channel per shaft group for the new network calibration test.
- usesA paired test did not detect increased high-gamma drift in annotated post-stimulation windows from 21 SEEG participants sci:sha256:0eb1cda13cce113a7a1fe70466917eeb0278c662b2155ce27ee9d36ce7636489
We used the raw retrieval manifest and BrainVision header reader through the immediate parent package. They enabled a fresh size and SHA-256 check of all 105 source files and a complete spectrum reconstruction.
- usesdoi:10.18112/openneuro.ds006519.v1.0.0
Source data for the 35 SEEG records analyzed in this publication; the exact version is 1.0.0.
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.