Signals from other shafts raised mean 120 to 500 ms SEEG forecast error with past calibration at ridge penalty 1 in eight patients
We tested whether early signals from other electrode shafts improve a late SEEG waveform forecast with past calibration. The public source was OpenNeuro ds004696 version 1.0.1. We used 317 conditions and 1,933 test pulses in eight patients. Each condition used five calibration pulses. Shared fitting used only other calibration groups that ended before the query input. At ridge penalty 1, added shaft inputs raised mean 120 to 500 ms forecast error by 4.27%. The 95% whole-patient bootstrap interval was 3.31% to 5.12%. Error rose in all eight patients. The unrestricted calculation matched the prior 1.82% error increase. At fixed penalty 10, the past-data increase was 0.29%, with an interval that included zero. All eight native source reconstructions matched the compact inputs exactly. Time checks, future-data changes, independent error calculations, and offline replay passed. The package preserves data, source hashes, code, forecasts, tables, three figures, and repeat instructions. This is an offline test of selected clinical data. It does not establish a deployed interface benefit or the absence of useful information in other shafts.
stereoelectroencephalography · brain-computer interface · forecasting · ridge regression · temporal validation · electrical stimulation
References
5- usesA shared early response update gave no clear 100–500 ms SEEG forecast gain after five calibration pulses in eight sessions sci:sha256:d08bfec8ec3877927777b5523fb915890ea9fe2bbb1c2ba2e47b0d5feb66f79c
We compared our result with its prior time-ordered scalar update test after our scores were calculated. Its voltage products, cohort, and model differ. Its data were not an input to this analysis.
- Early signals from other shafts raised mean 120 to 500 ms SEEG forecast error at ridge penalty 1 in eight patients sci:sha256:46f5503ded8a81eca04598cfbeb746a794fd8887884179d1c95ba18a55bc41b4
[Legacy relation: reproduces] All 64 primary unrestricted patient error values matched within 4.45e-16. We used its selected compact inputs, models, and source recipe. We then tested a new rule that permits only completed past donor calibration groups.
- usesMean rates of shared large errors in fixed SEEG waveform forecasts exceeded an independent pulse reference before and after pulses in eight people sci:sha256:450829ea4a2474fe15175fd53492702c0ade3f9d8500b65fe074084d20dbf994
Its native input recipe, source metadata, and pinned file manifests reached this work through the parent package. New downloads and native reconstruction checked all eight patients.
- usesdoi:10.18112/openneuro.ds004696.v1.0.1
This version of OpenNeuro ds004696 supplied the selected recordings used in the analysis.
- doi:10.1523/JNEUROSCI.2201-22.2023
Cited by
0 publicationsPublic catalog entries on Sciscape.