In 8 SEEG patients, stimulation-pair orientation did not predict other-shaft N1 occurrence or amplitude beyond distance
We tested if the axis of a bipolar SEEG stimulation pair changes which contacts on other shafts show an expert-checked N1 CCEP when distance is known. A dipole model predicts up to 2 times more field on-axis than at 90 degrees. We used 8 patients (STREEF06–13) from OpenNeuro ds005448 v1.0.0, with 334 pairs, 30,815 pair-contact rows, and 2,316 N1s. The plan was fixed and hashed before outcomes were computed. In each patient, we fit y ~ log d + |cos θ| and compared the angle coefficient with a null that exchanges pair axes between shafts (1,000 permutations). The mean coefficient was +0.06 (4 of 8 positive; exact sign-flip p = 0.88; 95% interval of odds ratio 0.46–2.44). Two patients were significant alone, in opposite directions. The angle changed held-out AUC by −0.001 to +0.007 (distance-only AUC 0.72–0.95). A fixed dipole-field term was worse than distance in 6 of 8 patients. The angle did not change N1 amplitude (p = 0.41). The permutation-null mean was not zero (−0.29 to +1.05), so a test without a geometry-aware null can show false orientation effects. This result agrees with a previous study using a different contact set and null. For bipolar single-pulse SEEG stimulation, pair orientation was not a useful control for targeting responses at other-shaft sites. Effects smaller than an odds ratio of about 2 are not excluded. The package includes the numpy code, hashed plan, input files with provenance, per-patient results, permutation nulls, and two figures.
SEEG · CCEP · N1 · brain stimulation · stimulation orientation · electrophysiology · epilepsy · permutation test · reproduction
References
3- usesDistance predicts expert-checked SEEG N1 responses; binary DTI connectivity adds little held-out prediction sci:sha256:6cf9c8c67a630f6ea95886ffb45e38fd368da616cd22c3440c677db88ad97d7c
We use its archived ds005448 input files (N1sChecked.mat, electrodes.tsv), its provenance table and its MAT-file reader.
- Stimulated pair angle did not improve distance-based prediction of N1 CCEPs in eight SEEG patients sci:sha256:92c46d80597ca98119714913166890cca61163bd1974101d103a8c1c646b3713
[Legacy relation: reproduces] Same question and patients; we used independent code, all N1sChecked channels with coordinates (30,815 vs 20,308 rows) and a shaft-axis exchange null. The result agrees: no orientation effect beyond distance.
- usesdoi:10.18112/openneuro.ds005448.v1.0.0
The analyzed expert-checked N1 labels and electrode coordinates came from OpenNeuro ds005448 v1.0.0 (STReEF), patients STREEF06–STREEF13. The saved dataset metadata reports CC0.
Cited by
2 publicationsPublic catalog entries on Sciscape.
- supportsSEEG shaft direction did not predict visual-percept current within patients, but steep shafts were rare
As for the CCEP N1 in ds005448, the direction of the stimulation pair did not change the stimulation effect, here for visual-percept current.
- usesA power law predicts held-out SEEG N1 amplitude better than an exponential law in 8 patients
We used its archived table results/rows.tsv.gz (distance, expert-checked N1 flag and N1 peak amplitude per stimulation pair and contact, ds005448) without change as the input of all tests.