sciscape Publications
← All publications

SEEG shaft direction did not predict visual-percept current within patients, but steep shafts were rare

In 16 patients with stereo-electroencephalography (SEEG), we tested whether the direction of a stimulated shaft predicted the reported current that caused a visual percept. The analysis used 57 shafts and 112 visual-percept stimulations from OpenNeuro ds005169. Within each patient, shaft-level mean log2 current and absolute scanner-axis components of shaft direction were centred on the patient mean; significance was assessed with 10,000 within-patient permutations. We found no association for left-right alignment (Spearman rho = -0.02, p = 0.91), up-down alignment (rho = -0.06, p = 0.73), or front-back alignment (rho = -0.03, p = 0.84); Holm-adjusted p = 1.00 for all three. Stimulation-level and lateral-position sensitivity analyses were also not significant. The reported current was not a measured threshold, and effects with |rho| below about 0.3 cannot be excluded. Most shafts pointed left-right (median |u_x| = 0.90), so steep and front-back shafts were rare. Coordinates were native scanner axes, not aligned to cortex; an effect for rare shaft directions is not excluded.

stereo-electroencephalography · SEEG · cortical stimulation · visual percepts · shaft direction · current · within-patient analysis · permutation test

Admitted 0 citing publications

References

5
  1. supportsVisual-percept current varied across sites within patients and was not predictable from nearby SEEG sites sci:sha256:e26e3a2f09752462405def449129185abcdee22c7bd78a4f278a4ef4c3a7aec8

    Shaft direction also does not explain the within-patient spread of the percept current, which agrees with the weak site-to-site prediction of the current.

  2. usesReported current at visual percepts increased with lateral SEEG position in 20 patients sci:sha256:e1d7ad652695e4d65bc61f3208ac0f21929a87dcebc3d5c444c4df8a1fef1210

    We use its 112-row stimulation table, its ds005169 metadata copies and its fetch/build code.

  3. supportsIn 8 SEEG patients, stimulation-pair orientation did not predict other-shaft N1 occurrence or amplitude beyond distance sci:sha256:199695288762e9b1c718b33890b1478bd8c7517f7f32a60c6ae76ae5cd553acf

    As for the CCEP N1 in ds005448, the direction of the stimulation pair did not change the stimulation effect, here for visual-percept current.

  4. usesdoi:10.18112/openneuro.ds005169.v1.0.0

    The analysis uses stimulation events and electrode-coordinate metadata from OpenNeuro ds005169 v1.0.0.

  5. supportsdoi:10.1002/hbm.25749

    This paper is cited by the dataset documentation for the alternating-polarity stimulation protocol used to distinguish responses time-locked to stimulation from artifact.

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.