sciscape Publications
← All publications

Four-pulse fitting reduced error but did not show smaller joint envelopes for 20–500 ms SEEG in eight sessions with five early pulses

We tested a five-pulse calibration budget for forecasts of stimulation responses. The public data were SEEG from eight epilepsy patients in OpenNeuro ds004696, version 1.0.1. We used 86 sites, 886 stimulation-to-readout pairs, and 430 later test pulses. Pulse 1 fixed the noise scales. The split rule used pulse 1 as its forecast. The full rank rule fitted pulses 2 to 5. Both rules had an 80 percent marginal target under conditional exchangeability. We proved the smallest fixed ball about the four-pulse mean that contains the full rank set. Its radius is 5/3 times the largest early residual in the fixed joint norm. At 20 to 500 ms, its geometric mean radius changed by -0.3 [-11.0, 10.2] percent relative to the split rule. Brackets give 95 percent patient bootstrap intervals. This result did not establish equal radii. Split-ball complete-pulse coverage was 77.3 [69.8, 83.5] percent. Exact full rank coverage was 79.8 [71.8, 86.0] percent. Full enclosing-ball coverage was 89.0 [84.1, 92.9] percent. Four-pulse fitting reduced the scaled mean squared forecast error from 8.64 to 4.43. The exact set and its ball must be assessed separately. Time-ordered pulses do not prove exchangeability. The study did not test a live BCI or a new session. The package contains exact trial products, source hashes, code, proof, figures, and reproduction instructions.

stereoelectroencephalography · brain stimulation · conformal prediction · joint coverage · calibration · forecasting · uncertainty quantification · neural responses

Admitted 1 citing publication

References

6
  1. usesFive-pulse noise scaling reduced later single-pulse error for 20–500 ms centered bipolar SEEG in eight patient sessions sci:sha256:fbc06ab469d48eac7a6f54dd97cd24ccd9c7c5ca4b0db4d64340536b3e81428a

    This publication supplied exact waveform products, corrected chronological event maps, source hashes, and retrieval code. Fresh source rebuilds matched these inputs.

  2. usesSeparate pair bounds covered 71.5 percent of individual SEEG responses and 17.0 percent of whole pulses at 20 to 500 ms in eight sessions sci:sha256:1a0ecb0d254415256c85ec04c2b9bce25a0f6893277ff47091e5d6c673436869

    This publication supplied the complete-pulse split-rank construction. We changed its fitting and calibration allocation to compare five early pulses at an 80 percent target.

  3. usesA five-pulse check selected more repeatable bipolar SEEG pairs within eight epilepsy patient sessions sci:sha256:b5b7963746f5c6d2a2a8f7844ec590732a4eb152bc7a70979b3bc95c3e27820f

    This publication defined the bipolar readout rules and the original compact extraction. We kept those rules for the fixed-budget test.

  4. usesA joint rank check accepted 83.2 percent of later SEEG responses at 20 to 500 ms in eight patients after five calibration pulses sci:sha256:293b34e71ea8d2f99a69e38b3c7c5227f6549f67906ebb9986851394508c542b

    This publication supplied the joint augmented-mean rank construction. We fixed the first-pulse scales and derived its smallest enclosing radius about the four-pulse mean.

  5. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    The study uses source SEEG derivatives from OpenNeuro ds004696 version 1.0.1.

  6. doi:10.1523/JNEUROSCI.2201-22.2023

Cited by

1 publication

Public catalog entries on Sciscape.