The mean spectral AUC gain stayed positive under up to one adjacent label exchange per patient. The test used fixed scores and onset counts in 31 SEEG patients.
We tested how changes in evaluation labels affect a fixed SEEG ranking result. The public source was OpenNeuro ds004100 version 1.1.3. We used archived scores for 31 patients, 2,879 contacts, and 271 onset labels. Each model excluded the test patient from training. The primary contrast compared contact number plus six CAR spectral features with contact number alone. The mean patient AUC gain was 0.074032. Under up to one adjacent positive-negative label exchange per patient, its exact range was 0.052324 to 0.079182. Adjacent contacts had consecutive final numbers in the same parsed name prefix. Scores and onset counts stayed fixed. The lower mean stayed positive over all allowed disjoint adjacent exchanges. When any two contacts in one prefix could exchange labels, 31 exchanges removed the mean gain. The exact lower mean was positive at a total budget of 30 and negative at 31. The latter changes moved 31 of 271 original onset labels. We provide integer and rational bound code, proofs, contact changes, frozen inputs, source recipes, and independent checks. These are exact bounds for hypothetical evaluation labels. They do not measure clinical label error or surgical benefit.
SEEG · seizure onset labels · AUC · label sensitivity · exact bounds · spectral features · ranking
References
4- usesSix CAR spectral features raised mean seizure onset label AUC beyond contact number. Fixed logistic tests excluded each of 31 SEEG patients. sci:sha256:aee5a470b0833c4f856b9a317fa6e6005828d574f583119a67ef17a72b7a7b3f
This publication supplied the fixed test scores, contact features, model parameters, and patient selection used for the exact label bounds.
- usesIn 30-second HUP SEEG samples, reference changes reduced mean 30–100 Hz slope rank agreement more than run changes sci:sha256:b9c7b4646dba303292f492835f91dbb8026d4f35fcce938519d1d3fa6bcbff63
This publication supplied the source spectra, metadata, and pinned signal retrieval code through the direct score archive. We used them to check features and two raw signal excerpts.
- usesdoi:10.18112/openneuro.ds004100.v1.1.3
Version 1.1.3 of the HUP iEEG Epilepsy Dataset supplied the source SEEG recordings and labels represented in the archived fixed score inputs.
- doi:10.64898/2026.01.15.26344025
This preprint motivated testing sensitivity to expert onset-channel annotation; its recordings and annotations were not used.
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.