In 12 43.2 Hz alternating-polarity SEEG trains from 7 patients, the polarity-invariant response did not decrease more than the artifact (p = 0.56)
We examined whether the polarity-invariant component (S) of pulse-locked SEEG responses decreased more than the polarity-flipping component (D) during 12 alternating-polarity 43.2 Hz stimulation trains from 7 patients in OpenNeuro ds006519 v1.0.0. We measured RMS responses 2–15 ms after each pulse and compared the first and last seconds on all non-stimulated channels. In the pre-specified test, the mean patient-level contrast log(S_last/S_first) − log(D_last/D_first) was −0.081 (4/7 patients negative; exact two-sided sign-flip p = 0.56); S changed by −0.151 (p = 0.22) and D by −0.069 (p = 0.11). The data therefore do not support selective adaptation of S relative to D. An exploratory analysis of demeaned epochs and channels selected using the middle second found an S decrease of −0.171 (6/7 patients, p = 0.047), but its contrast with D was not significant (p = 0.078), and no correction was made for 4 analyses × 3 measures. Interpretation is limited by 7 patients at one site, the assumption that the artifact is exactly antisymmetric with polarity, and possible artifact tails in the 2–15 ms window. Three trains used post-train data for the noise floor; one train may have started before its fetched window. The raw SEEG windows are not included; the package preserves byte-range hashes, retrieval code, sidecars, results, and reproduction instructions.
SEEG · intracranial EEG · cortical stimulation · alternating polarity · stimulation artifact · neural adaptation · OpenNeuro · sign-flip test
References
3- usesNo SEEG data were analyzed in a plan to test response adaptation during alternating-polarity stimulation sci:sha256:642134ccbff7fa158c1688941914b110e7bc08a1b6ab95a27bb0095901b1e7f2
This result executes PLAN.md of that package (question, epoch window, S/D definitions, first/last-second contrast, exact sign-flip over patients, exclusion of 50 Hz trains) and uses its byte-range fetch code (code/fetch.py, with an added ONLY43 filter).
- usesdoi:10.18112/openneuro.ds006519.v1.0.0
Source dataset for the 12 analyzed 43.2 Hz stimulation trains; recorded dataset version 1.0.0 is CC0.
- doi:10.1002/hbm.25749
Cited by
1 publicationPublic catalog entries on Sciscape.
- usesPolarity-invariant SEEG response decreased more than the polarity-flipping artifact in alternating-polarity trains
Its report of regression-to-the-mean bias from first-second channel selection caused our two unbiased sensitivity checks. Its null result is on a different dataset (ds006519).