A fixed acoustic distance rule failed a shared error rank test in 20 iEEG patients and 24 fMRI adults
We tested whether acoustic distance warns of neural encoding error beyond feature size and predicted response power. Separate public studies supplied signed iEEG local field potential and BOLD fMRI. Five patients and four adults supplied development. Fixed tests used 20 other patients, 16 B2021 adults and eight NH2015 adults. Models trained on 95 or 110 sounds and tested 48 or 55 other sounds. Mean adjusted rank scores were 0.07186, 0.13515 and 0.06606. Their 95% person intervals were [0.01992,0.12380], [0.09810,0.17220] and [-0.03816,0.17029]. The three-cohort rule failed, p=0.08879. All person-and-test-sound resample ranges included zero. Negative scores and all fixed controls remain. All 44 fixed unbounded response models had negative skill against their training means. A later exploratory input-clipping check gave positive skill in 41 people, but warning scores shrank or changed sign. A near-zero mean inflated one normalized variability descriptor in the MRI cough clip. An exact fixed-design example also gives growing distance with constant expected error. These checks limit interpretation; they are not fitted neural causes. Independent arithmetic checked all 44 primary people. The contribution is a reproducible failed warning benchmark and model diagnostic. It does not establish cross-modal warning generalization. Source selection, different cohorts and sounds, measurement noise, fixed fits and descriptor choices limit scope. Code, permitted electrical inputs, provenance, all outcomes, figures and repeat steps are supplied.
human neuroscience · iEEG · fMRI · acoustic encoding · model error · uncertainty · replication · negative result
References
11- usesFixed acoustic metrics did not pass a shared transfer test in 20 iEEG patients and 16 fMRI adults sci:sha256:5b3c14f7e26e96a03be6fd767f0bb3e600b235803a998b6dc7cb9a9df4d28128
Licensed electrical derivative, fixed source pins and MIT source readers.
- usesFor 165 sounds, mean scores for own sound maps exceeded scores for other people in six SEEG patients and two fMRI cohorts sci:sha256:1132188e798487dc9d518e23dd835f89be7c79e2dec515090a981aefa38125d3
MRI selection reader and source provenance.
- Error maps from other people improved forecasts in 14 fMRI adults but failed a shared test with 18 iEEG patients sci:sha256:78f975017366d6a34c95d1b7772d4d20eccf19397fc40a806b2f0d8ad9c4c5ed
Related model-error forecast test and prior input clipping.
- Input clipping left an uncertain mean gain for smooth acoustic models in 20 iEEG patients and a positive gain in 20 fMRI adults sci:sha256:8ce8db4b5312116aba279dc9c273212d0b6bb882dfd420359de40e6fb392c65a
Prior study of input clipping in the reused source datasets.
- doi:10.1016/j.cub.2026.07.063
- doi:10.5281/zenodo.20599001
- doi:10.1152/jn.00588.2020
- doi:10.1016/j.neuron.2015.11.035
- doi:10.1371/journal.pbio.3002366
- doi:10.1109/TAFFC.2015.2457417
- doi:10.1016/j.cub.2022.01.069
Cited by
1 publicationPublic catalog entries on Sciscape.
- At an 80% target, limits set with other sounds gave lower mean coverage for voices in 20 iEEG patients and 24 fMRI adults
Prior error-ranking test on related public source studies.