Error maps from other people improved forecasts in 14 fMRI adults but failed a shared test with 18 iEEG patients
We tested if sound error maps from other people improve forecasts of errors from a clipped acoustic response model. Separate public studies supplied signed iEEG LFP and BOLD fMRI. Six people per study supplied development and reference maps. A local code lock preceded tests in 18 other patients and 14 other adults. Nested sound folds excluded each target response from both response fitting and error calibration. Base forecasts controlled voice class, acoustic distance, feature norm and predicted response norm. The mean log-error forecast gain was -0.991% in iEEG and +37.057% in fMRI. Pointwise 95% person intervals were [-1.702%, -0.281%] and [32.426%, 41.687%]. Gains were positive in 3/18 and 14/14 people. The shared positive test failed, with person sign conjunction p=0.999344. Common sound controls, donor and sound sensitivity ranges, site-count checks and repeat estimates remain. Exact source extraction matched all retained electrical arrays. Independent fits and a clean primary replay checked the results. At three sampled sites per person, the fMRI mean gain fell to 0.837%, with an interval across zero. The useful forecast is limited to full selected BOLD panels with target calibration. Source selection, clinical sampling, unequal tissue and measurement filters prevent a causal modality claim. No cross-modal generalization or shared neural cause is established. The package preserves code, permitted data, source versions and terms, all results, figures, plans and repeat instructions.
human neuroscience · intracranial EEG · fMRI · auditory encoding · model error · cross participant transfer · negative results
References
8- usesInput clipping left an uncertain mean gain for smooth acoustic models in 20 iEEG patients and a positive gain in 20 fMRI adults sci:sha256:8ce8db4b5312116aba279dc9c273212d0b6bb882dfd420359de40e6fb392c65a
We reuse its licensed electrical derivative and MIT source readers. Its clipping result motivates the robust acoustic reference.
- Fixed donor sound models lowered test error for selected iEEG means in six patients and auditory BOLD in 20 adults with 120 s target fits sci:sha256:92398dbc1c1839b950eced533e99751e2e9b0e1a9c5e52b6a5e4213b080f43bd
Related donor response transfer tool in other iEEG and fMRI cohorts; our endpoint forecasts model errors.
- usesdoi:10.5281/zenodo.20599001
- usesdoi:10.1016/j.cub.2026.07.063
- usesdoi:10.1152/jn.00588.2020
- usesdoi:10.1371/journal.pbio.3002366
- usesdoi:10.1016/j.cub.2022.01.069
- supportsdoi:10.1371/journal.pcbi.1006397
Cited by
5 publicationsPublic catalog entries on Sciscape.
- A fixed acoustic distance rule failed a shared error rank test in 20 iEEG patients and 24 fMRI adults
Related model-error forecast test and prior input clipping.
- For fixed sounds, kernels from four source people lowered mean error in iEEG and B2021 fMRI; NH2015 gain was uncertain
Prior source-person error-map transfer failed in electrical data. We test neural response prediction, retain that negative result, and do not treat our result as an error-forecast replication.
- For fixed sounds, panels learned from other people lowered mean prediction error in 20 iEEG patients and 16 fMRI adults
- usesReference error scales did not pass shared tests in 20 iEEG patients and 16 fMRI adults
Prior error forecast test failed in iEEG.
- A fixed class relation rule failed a shared gain test in 20 iEEG patients and 16 fMRI adults
Prior prediction of sound error from other people motivated a direct error baseline.