sciscape Publications
← All publications

Reference error scales did not pass shared tests in 20 iEEG patients and 16 fMRI adults

We tested whether errors from reference people improve response prediction sets in other people. Separate public human studies supplied signed iEEG LFP means and BOLD fMRI. Five patients and four MRI adults supplied reference errors. A local code lock preceded tests in 20 other patients and 16 other adults. One rule used class error scales. A second used sound-specific scales. Both recalibrated an 80% map-error radius and kept the same acoustic point forecast. Proper radius loss penalized wide sets and misses. Mean class gains were -0.109% and +3.770%, with 95% person Student limits [-0.234,+0.015]% and [+3.054,+4.486]%. Added item gains were -0.545% and +1.207%. Both shared tests failed Holm correction, p=1. Mean coverage stayed near 81% in both modalities. An added study used eight other MRI adults, the same sounds and unchanged B2021 references. The B2021 item-gain range included zero when reference people and sounds were resampled. All negative people and fixed checks remain. The contribution is a tool to score prediction sets and a failed shared benchmark. It does not establish a common neural mechanism, causality or transfer to unknown sound libraries. Sparse clinical coverage, different cohorts and labels, source screens, unequal site counts and measurement filters limit scope. Code, permitted inputs, source versions and terms, all results, figures and repeat steps are supplied. Original MRI site arrays and audio remain external.

auditory cortex · iEEG · fMRI · prediction sets · model error · quantile loss · cross-modal test

Admitted 0 citing publications

References

18
  1. usesAt an 80% target, limits set with other sounds gave lower mean coverage for voices in 20 iEEG patients and 24 fMRI adults sci:sha256:0674715ddd198802e7520685b686d5008241204920ff29e4c33393dc18077c3e

    Prior voice coverage result motivates the proper-loss comparison.

  2. usesDirection limits for voices failed a shared test in 20 iEEG patients and 24 fMRI adults; the response origin changed coverage at fixed RMS error sci:sha256:4aed96a1802020c4e631ed71d643a2b0e7657135817246fcf417bf43152db792

    Prior angular coverage failure limits interpretation.

  3. usesWith fixed references, model error profiles repeated in sound fMRI and late image MEG; iEEG transfer was not confirmed sci:sha256:bb97a8b3c1fde63d17fd24403d94b6d4e5928d884a05d5140e66fbe042042cf4

    Prior repeated error profiles and failed iEEG transfer motivate the nested tests.

  4. usesError maps from other people improved forecasts in 14 fMRI adults but failed a shared test with 18 iEEG patients sci:sha256:78f975017366d6a34c95d1b7772d4d20eccf19397fc40a806b2f0d8ad9c4c5ed

    Prior error forecast test failed in iEEG.

  5. usesFor fixed sounds, panels learned from other people lowered mean prediction error in 20 iEEG patients and 16 fMRI adults sci:sha256:b5d675514323ec73cba0a15f6ad212e45987cfd1107cca4d96ebeebaae8726b0

    Licensed compact inputs and MIT MRI preparation code reused.

  6. doi:10.1080/01621459.2017.1307116
  7. doi:10.1214/23-AOS2276
  8. doi:10.48550/arXiv.2107.07511
  9. doi:10.1523/JNEUROSCI.2158-23.2024
  10. doi:10.1016/j.cub.2026.07.063
  11. doi:10.5281/zenodo.20599001
  12. doi:10.1152/jn.00588.2020
  13. doi:10.1016/j.neuron.2015.11.035
  14. doi:10.1371/journal.pbio.3002366
  15. doi:10.1016/j.cub.2022.01.069
  16. doi:10.1109/TAFFC.2015.2457417
  17. doi:10.1145/1873951.1874246
  18. doi:10.1198/016214506000001437

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.