For fixed sounds, panels learned from other people lowered mean prediction error in 20 iEEG patients and 16 fMRI adults
We tested whether responses from other people can choose useful calibration sounds. Separate public studies supplied signed iEEG LFP means and BOLD fMRI. Five patients and four MRI adults trained separate panels. A local code and panel lock preceded tests in 20 other patients and 16 other adults. These are new endpoints in reused public studies, not newly recruited cohorts. Each 32-sound learned panel had the same category counts as its acoustic reference. All future-person fits used the same ten-component acoustic regression. Mean sound-contrast error gains over acoustic selection were 2.161% and 5.856%, with 95% person Student intervals [0.919,3.402]% and [5.447,6.265]%. Gains over matched random panels were 2.200% and 8.010%. Mean skill over a constant forecast was 5.492% and 17.890%. The single shared gain-and-skill rule passed, p=0.000866092. Eight adults from another MRI study gave acoustic-comparison gain 3.935% with the unchanged MRI panels. The MRI studies share sounds. Common-sound and person reweighting kept positive ranges with fitted panels fixed. All negative people and descriptive controls remain. Reference target responses are required, so this is a known-library method for other people. It does not establish transfer to unknown libraries, prospective recording-time savings, a common neural source or causality. Clinical sampling, source screens, cohort differences, unequal features and measurement filters limit scope. The package preserves code, permitted inputs, source pins and terms, learned panels, residual summaries, all results, figures and repeat instructions. Original MRI arrays and audio stay external.
auditory cortex · stimulus selection · intracranial EEG · fMRI · cross-person prediction · optimal design
References
15- usesWith one fixed penalty, acoustic sound selection failed a shared test in 20 iEEG patients and 16 fMRI adults sci:sha256:3a52b9e0450816d80dee19095a3cf2f87e84b47d41305604fbde6c4a03f9787d
Its failed acoustic design benchmark informs the question, contrast loss and accuracy gate.
- usesFor 54 sounds, donor panel gains were uncertain in six SEEG patients and positive in 24 fMRI adults sci:sha256:63515a42466fb58197aea42a12d7f1584316262a1a1d72c21841b9b06d4b8937
Prior neural donor panel benchmark and its negative shared result limit novelty and interpretation.
- Error maps from other people improved forecasts in 14 fMRI adults but failed a shared test with 18 iEEG patients sci:sha256:78f975017366d6a34c95d1b7772d4d20eccf19397fc40a806b2f0d8ad9c4c5ed
- usesMaps fit to other sound classes predicted fixed animal sound patterns in 20 iEEG patients and 16 fMRI adults sci:sha256:1b8693e8389d334be8780044f5056e91081fd0c71bf35ea03565a0b417773b48
Reuse attributed licensed compact inputs, MIT source preparation and audit code, and source pins.
- doi:10.1162/NECO_a_00615
- doi:10.1198/TECH.2009.0008
- doi:10.1162/IMAG.a.1349
- doi:10.1016/j.cub.2026.07.063
- doi:10.5281/zenodo.20599001
- doi:10.1152/jn.00588.2020
- doi:10.1016/j.neuron.2015.11.035
- doi:10.1371/journal.pbio.3002366
- doi:10.1109/TAFFC.2015.2457417
- doi:10.1145/1873951.1874246
- doi:10.1016/j.cub.2022.01.069
Cited by
5 publicationsPublic catalog entries on Sciscape.
- usesA quadratic model failed a shared sound prediction test in 20 iEEG patients and 16 fMRI adults with whole groups excluded
Reuses attributed CC BY compact electrical and acoustic inputs, MIT source preparation and selected-byte audit code, and pinned source provenance.
- usesSixteen acoustic directions failed a shared prediction gain test in 20 iEEG patients and 16 fMRI adults
We reuse its licensed compact inputs and unchanged MIT source readers, with full upstream attribution.
- usesFitted reference weights failed a shared prediction test in 20 iEEG patients and 16 fMRI adults at 48 calibration sounds
Reuses licensed compact inputs, source pins and MIT MRI preparation and source-audit code; extends panel design work with a reference-weight prediction test.
- usesWith 32 calibration sounds, acoustic prior transfer failed a shared test in 20 iEEG patients and 16 fMRI adults
Reuse its licensed compact inputs, pinned MRI reader, source byte-range reader, notices, and person split; test a new covariance-prior transfer question.
- usesReference error scales did not pass shared tests in 20 iEEG patients and 16 fMRI adults
Licensed compact inputs and MIT MRI preparation code reused.