With 32 calibration sounds, acoustic prior transfer failed a shared test in 20 iEEG patients and 16 fMRI adults
We tested whether acoustic coefficient priors transfer between separate human iEEG and fMRI studies. A local lock fixed a 32-sound test in 20 patients and 16 MRI adults. The shared gain-and-skill rule failed, p=0.088217. Mean gains were 0.467% in iEEG and 2.433% in MRI. A planned 64-sound check later passed a Holm correction across 15 diagnostic propositions, p=0.010176. Mean gains were 0.986% [0.436,1.536]% and 0.334% [0.170,0.499]%. Brackets give pointwise 95% person Student limits. This inference is exploratory and reuses the primary people. The 64-sound MRI gain did not clearly exceed shuffled source references; its within-category reference fraction was 0.700. Its person/common-sound gain range also included zero. Thus no shared neural tuning benefit was confirmed. A separate eight-adult MRI study gave a positive 32-sound gain. The method uses 86 documented acoustic features, ten common components, source coefficient covariances, and separate target penalty selection. It needs no match of people, sites, or sounds between electrical and MRI studies. An exact noise limit shows that source acoustic design alone can give a non-isotropic prior. All negative people, controls, and a one-factor limit model remain. This is a tool and benchmark result for fixed libraries. It does not establish a common neural cause, equal signals, broad new-sound transfer, or causality. The package has code, permitted inputs, source pins and terms, all outcomes, figures, and repeat instructions.
human neuroscience · intracranial EEG · fMRI · auditory cortex · encoding models · covariance prior · transfer learning · negative result
References
15- usesFor fixed sounds, panels learned from other people lowered mean prediction error in 20 iEEG patients and 16 fMRI adults sci:sha256:b5d675514323ec73cba0a15f6ad212e45987cfd1107cca4d96ebeebaae8726b0
Reuse its licensed compact inputs, pinned MRI reader, source byte-range reader, notices, and person split; test a new covariance-prior transfer question.
- usesMaps fit to other sound classes predicted fixed animal sound patterns in 20 iEEG patients and 16 fMRI adults sci:sha256:1b8693e8389d334be8780044f5056e91081fd0c71bf35ea03565a0b417773b48
Upstream electrical compact means and attributed reader code, obtained through SCI 479585e9.
- usesTwo fixed acoustic rules did not confirm shared nonvoice prediction gains in 18 SEEG patients and two fMRI groups sci:sha256:f6ade96a55abd5dd6909603449b3d63ad197279407aa009d924a3be21ddc98ae
Upstream licensed MRI acoustic measurements, obtained through SCI 479585e9.
- With one fixed penalty, acoustic sound selection failed a shared test in 20 iEEG patients and 16 fMRI adults sci:sha256:3a52b9e0450816d80dee19095a3cf2f87e84b47d41305604fbde6c4a03f9787d
Related failed acoustic calibration design benchmark; catalog abstract inspected.
- usesOne bit per auditory site gave mean four-class accuracy above chance in 20 iEEG patients and 16 fMRI adults sci:sha256:640399d48b2742bcc4d3c828910fda08a928b409a54c25a630f3a8b53642c0c2
Upstream original-source chunk map and licensed electrical/baseline summaries, obtained through SCI 479585e9 and cf4efd8f.
- doi:10.1016/j.neuroimage.2019.04.012
- doi:10.1371/journal.pbio.3002366
- doi:10.1109/TAFFC.2015.2457417
- doi:10.1145/1873951.1874246
- doi:10.1016/j.cub.2026.07.063
- doi:10.5281/zenodo.20599001
- doi:10.1152/jn.00588.2020
- doi:10.1016/j.neuron.2015.11.035
- doi:10.1038/35002078
- doi:10.1016/j.cub.2022.01.069
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.