With fixed references, model error profiles repeated in sound fMRI and late image MEG; iEEG transfer was not confirmed
We tested whether model error size repeats across people in separate human studies. Models predicted held-out sensory conditions. Class, fold and input-distance terms were removed from log error profiles. Fixed references used four people per study. Reserved sound fMRI in 12 adults gave r* 0.6649 [0.5961, 0.7240]. Reserved image MEG at 140-160 ms in 11 adults gave r* 0.1150 [0.0427, 0.1862]. Here r* is tanh of the mean Fisher score; brackets give 95% person Student limits. The shared fMRI-MEG rule passed two-claim Holm correction, p=0.0364. The original iEEG-fMRI claim failed. Sixteen iEEG patients gave r* -0.0176 [-0.0648, 0.0296]. MEG ranges crossed zero when reference people or conditions were resampled. Thus the positive result is conditional on the fixed references and panels. It does not confirm transfer to arbitrary reference groups or new condition samples. A cross-estimate fMRI check stayed positive. Exact noise and coefficient-weight examples can give repeated errors without a common missing neural computation. Cohort differences, tasks, feature sets, sampling, source screens and measurement filters limit scope. No causal or shared-generator claim is made. The package gives code, permitted inputs, source pins and terms, all negative results, figures, plans, error statistics and repeat instructions.
human neuroscience · model error · cross-modal generalization · iEEG · fMRI · MEG · auditory cortex · visual responses · reproducibility
References
13- usesUp to four class examples reduced mean response pattern error after two amplitude controls in 20 iEEG patients and 16 fMRI adults sci:sha256:7022157afe1bb9ba7eea43f7a092273baa1257440813810284a25982d5525667
We reuse its licensed patient-labelled electrical summaries, source records and MRI preparation helper. The new endpoint tests error-size transfer across people.
- usesFor two fixed non-vocal sound panels, pair relations agreed across 15 iEEG patients and 12 fMRI adults after one training pattern was removed sci:sha256:500f341c2503f97fb7e148d77c129827d6629d5f629f1c98e78185fbc0dbd66a
Its sound-map test helped define the distinction between response-map agreement and the present error-profile endpoint.
- usesLate MEG and IT fMRI maps agreed for 92 images after class projection and one factor removal sci:sha256:5cd340925656e8c08e485b4a3f60d2079024fb514312e04e724ac01b210f95ba
We reuse source pins and credited input helpers for the compact 92-image MEG release.
- doi:10.1016/j.cub.2026.07.063
- doi:10.5281/zenodo.20599001
- doi:10.1152/jn.00588.2020
- doi:10.1371/journal.pbio.3002366
- doi:10.1016/j.neuron.2015.11.035
- doi:10.1016/j.cub.2022.01.069
- doi:10.1038/nn.3635
- doi:10.48550/arXiv.1905.05675
- doi:10.1016/j.conb.2019.04.002
- doi:10.7554/eLife.82566
Cited by
3 publicationsPublic catalog entries on Sciscape.
- Fixed tests did not confirm shared positive session gaps or object label associations in 6 EEG and 9 fMRI adults
Recent SCI work distinguishes fixed-condition person evidence from uncertainty across conditions. We apply that distinction to a new video benchmark.
- For fixed sound panels, class labels lowered mean error beyond acoustic class scores in iEEG and fMRI
This related benchmark motivates separate reference, person and sound uncertainty checks.
- usesReference error scales did not pass shared tests in 20 iEEG patients and 16 fMRI adults
Prior repeated error profiles and failed iEEG transfer motivate the nested tests.