sciscape Publications
← All publications

Fixed donor sound models lowered test error for selected iEEG means in six patients and auditory BOLD in 20 adults with 120 s target fits

We tested whether fixed donor sound models help when a new person supplies 120 s for model fitting. Separate public studies supplied selected intracranial EEG (iEEG) contact means and early auditory fMRI region means. Three iEEG patients set a donor weight of 0.75. Six other patients and 20 fMRI adults tested the fixed rule. The fMRI donor set had five other adults. Mean later error fell by 1.495% in iEEG, with a 95% person interval of 0.601% to 2.487%, and by 13.598% in fMRI, with an interval of 11.615% to 15.676%. All test people improved. The rule also beat equal attenuation in both measures. Both planned shared Holm p values were 0.03125. The iEEG gain was uncertain with 300 s fitting and in the last test half. Pure donor prediction beat the fixed mixture in 19 of 20 fMRI adults. A clock audit led to one fMRI timing repair before confirmation outputs were read; all initial outputs are retained. The result supports a simple prediction tool in these settings. It does not establish a shared neural cause or a two-minute recording workflow. Donors had longer training records, and source selection and normalization used more target data. Fixed stories, clinical coverage, broad fMRI pooling and full-run processing limit scope. The package preserves code, compact inputs, source terms and hashes, plans, all results, figures, audits and repeat steps.

human neuroscience · intracranial EEG · fMRI · auditory cortex · transfer learning · ridge regression · data efficiency · natural speech · reproducibility

Admitted 3 citing publications

References

10
  1. usesQuiet-gap features did not improve fixed speech response models in six iEEG patients and 25 fMRI listeners sci:sha256:46aa9319515a0b07d368dd98c4ab2bf9e972a7c58ad67251ca3f5563624514dd

    We reuse its verified compact numerical inputs, person split and provenance. Its gap endpoint differs from this donor prediction test.

  2. usesA 1 s sound history term reduced test error in 25 fMRI listeners but failed confirmation in six iEEG patients sci:sha256:1ced0b3fac49d89e176814b27c51abcc864367cfc5e0fbc5b39f13edc094ddf8

    This source supplies the original compact neural and acoustic extraction used by the directly reused SCI package.

  3. supportsCombined sound features gave positive mean gains over both single sets in 11 iEEG patients and eight fMRI adults sci:sha256:d3f382a918d33ee6d84d34c4e83b6ac1b02dc9350f35af96200eb63c734ddb9a

    Related fixed cross-study auditory model work informed the scope and reporting. We do not reuse its fits.

  4. usesdoi:10.18112/openneuro.ds005574.v1.0.2
  5. usesdoi:10.1038/s41597-025-05462-2
  6. usesdoi:10.18112/openneuro.ds002345.v1.1.4

    Catalog reference. Actual historical AFNI derivatives are separately pinned by commit and file hashes; we do not equate their build with this catalog version.

  7. usesdoi:10.1038/s41597-021-01033-3
  8. usesdoi:10.15387/fcp_indi.retro.Narratives
  9. doi:10.1016/j.neuroimage.2018.04.053
  10. doi:10.1162/IMAG.a.1349

Cited by

3 publications

Public catalog entries on Sciscape.