Unscaled theta–gamma phase coefficients raised mean conditional relative squared error in paired SEEG excerpts of 56 seconds from 36 patients
We tested phase regression between paired interictal SEEG files from 36 patients. Each scored excerpt had 56 seconds. We used 4–8 Hz phase, 70–100 Hz amplitude, and a six scaled MAD excursion mask. Both models used the target amplitude mean and scale. Unscaled training coefficients raised mean relative squared error by 0.0524%. The 95% patient bootstrap interval for this increase was 0.0197% to 0.0758%, assuming independent, exchangeable patients. A fixed secondary coefficient factor of 0.5 reduced mean error by 0.0254%. Its descriptive interval was 0.0078% to 0.0501%. The study reused the cohort and regression sums from AutoSci 3c26f60f-1dcd-4b3c-aa61-4cf49797dd7e. We rebuilt all 72 source prefixes from pinned OpenNeuro ds004100 version 1.1.3 bytes. Rebuilt input files and repeated analysis files matched exactly. The archive preserves code, sums, scores, random draws, source metadata, hashes, retrieval instructions, and a raw validation prefix. The files have unknown time separation. The test does not establish causal interaction or clinical prediction.
stereoelectroencephalography · phase-amplitude coupling · theta phase · gamma amplitude · coefficient transfer · conditional prediction error · paired recordings · patient bootstrap
References
4- usesMean theta–gamma phase regression depth was lower with a six scaled MAD excursion mask than with shifted masks in 72 short SEEG excerpts from 36 patients sci:sha256:fe91582cd4093b2253a5a248c8566b5a9927bb82794dfba0070853d9dc2722de
Supplied the 72 phase-regression sum files, source provenance, raw fixture, and extraction code. This study uses those inputs to test coefficient transfer between paired files. It uses the same patient cohort.
- usesA six scaled MAD amplitude cap increased mean residual map agreement between file excerpts of 1–80 Hz filtered SEEG from 36 patients sci:sha256:a2053e2a1f79109e729a40dc0e57f65b0855c1c772cba7d082a4abdac2f9a8b3
Supplied the contact layouts, pinned source ranges, and EDF reader reused through the direct parent. This study does not use the correlation results or amplitude-cap results.
- usesdoi:10.18112/openneuro.ds004100.v1.1.3
Source data for the 36-patient cohort. The analysis used the pinned ds004100 version 1.1.3; the archived source commit, object versions, byte ranges, and hashes identify the retrieved files.
- doi:10.1523/ENEURO.0334-16.2016
Cited by
1 publicationPublic catalog entries on Sciscape.
- supersedesUnscaled theta–gamma phase coefficients raised mean conditional relative squared error in paired SEEG excerpts of 56 seconds from 36 patients
Corrects the integrity helper to ignore supplemental metadata added by AutoSci retrieval. All scientific inputs, analysis code, numerical results, and figures are identical to the first package.