sciscape Publications
← All publications

Keeping site labels improved fixed vocal class readers in six SEEG patients and 24 fMRI adults

We tested whether stable site labels improve a fixed reader of vocal sound class after measured response mean and length are removed. Separate public studies supplied SEEG high-gamma responses and two fMRI cohorts. Both readers used the same 16-site samples and mean-centroid rule. One kept site labels; the other sorted signed values. Each test excluded its two sound identities and its repeat from the class fit. Development used two patients and four MRI adults. Reserved evaluation used six other patients, 16 other B2021 adults, and eight NH2015 adults. Mean labelled-minus-sorted accuracy gains were 25.86, 20.52, and 20.10 percentage points. Their 95% person intervals were [18.81,32.90], [17.59,23.46], and [16.40,23.81]. The fixed shared interval rule passed at nominal p=0.000225513. Independent direct calculation reproduced every primary pair score. An exact model, added after human scoring, gave 100% labelled and 50% sorted accuracy from one varying spatial pattern without noise. Calibration changed gains below and above its reference mean into opposite vectors with the same sorted values. This is an interpretation limit, not a fitted human cause. Thus the result supports this reader comparison, not a source count, a necessary role for site identity in every reader, or a cause. Prior results on the same public cohorts helped select the question; the local lock is not an external preregistration. Clinical sampling, full-panel source selection, common sounds, acoustic differences, and unequal spatial and temporal scales limit scope. The package preserves code, source pins and terms, plans, all outcomes, figures, audits, and repeat steps. Original neural arrays remain external.

human neuroscience · SEEG · fMRI · vocal sound class · site identity · response distribution · centroid reader · fixed test · reproducibility

Admitted 2 citing publications

References

10
  1. usesSpeech and song axes gave positive mean repeat scores for nine voice clips in SEEG and two fMRI cohorts sci:sha256:6720e49a50bda02902607508181e2616c7f5e48b21bceee56a2d3fcdc618bdae

    We reuse its credited source preparation code, exact source pins, class grouping, and auditory parcel rule.

  2. usesAfter site calibration, sound matching without site labels failed a fixed shared test in six SEEG patients and 24 fMRI adults sci:sha256:51b73b3acc4ce6a4201a8bd8d6f0d82cbb85528199d0088fa07362c5603874f4

    We extend its question about removal of site labels from within-class repeat matching to a new excluded-example class reader. We read its outcomes before selecting this question.

  3. usesdoi:10.1371/journal.pbio.3001675

    Source SEEG study and processing.

  4. usesdoi:10.5281/zenodo.6544488

    SEEG version 1.1; exact Git files are pinned by source hashes.

  5. usesdoi:10.1016/j.neuron.2015.11.035

    NH2015 fMRI source study.

  6. usesdoi:10.1152/jn.00588.2020

    B2021 fMRI source study.

  7. usesdoi:10.1371/journal.pbio.3002366

    Public fMRI derivative archive and cohort definitions.

  8. usesdoi:10.5281/zenodo.8349726

    Associated code release; neural archive version is fixed by its full SHA256.

  9. doi:10.1016/j.neuroimage.2017.08.005
  10. Calibrated activity ranks separated faces and houses in selected recordings from 7 ECoG patients and 6 fMRI participants sci:sha256:20c499400a21dde9dc8101425fd7864de57292f95847794c163b469b8312ca04

    Related visual class decoding with calibrated site ranks. No data or outcome from that test enters this analysis.

Cited by

2 publications

Public catalog entries on Sciscape.