After site calibration, sound matching without site labels failed a fixed shared test in six SEEG patients and 24 fMRI adults
We tested whether calibrated response magnitude distributions support repeated sound assignment without target site labels. Separate public human studies supplied SEEG high-gamma activity and fMRI BOLD estimates. Calibration used other sounds. Targets lost their spatial mean, vector length, global sign and site order. A reader assigned two sounds within one broad class to templates from another repeat. Development used two patients and four adults. Fixed tests used six other patients, 16 B2021 adults and eight NH2015 adults. Mean accuracies were 52.21%, 56.06% and 52.94%. Their 95% person t intervals were [49.50,54.92]%, [54.26,57.86]% and [50.59,55.30]%. The shared rule failed, p=0.090626. Both fMRI component rules passed. Joint person-and-sound resampling included chance for SEEG and NH2015. No positive cross-modal generalization was confirmed. All fixed controls and negative person scores remain. One concentration value gave positive pointwise MRI intervals. Noiseless one-direction signals gave ties; one direction plus independent private normal errors gave positive scores. A population moment calculation explains how signal-to-noise ratio can remain in normalized magnitude distributions. These examples were not fit to people. Source audits exactly rebuilt 784080 electrical window means and 9665865 selected MRI values. Separate cohorts, unequal sites, clinical sampling, shared schedules and source selection limit neural claims. The contribution is a new assay, a scoped negative shared result and a tested observation-model limit. The package gives code, source pins and terms, all statistics, figures, local plans and repeat instructions. Original neural arrays remain external.
auditory cortex · SEEG · fMRI · sound matching · magnitude distributions · normalization · private noise · negative result
References
12- usesdoi:10.1371/journal.pbio.3001675
SEEG source study.
- usesdoi:10.5281/zenodo.6544488
SEEG source data, version v1.1, fixed Git commit and hashes.
- usesdoi:10.1152/jn.00588.2020
B2021 fMRI source study.
- usesdoi:10.1016/j.neuron.2015.11.035
NH2015 fMRI source study.
- usesdoi:10.1371/journal.pbio.3002366
Public fMRI author derivative archive and its cohort and preprocessing description.
- usesdoi:10.5281/zenodo.8349726
Code release associated with the public fMRI archive.
- usesFor 165 fixed sounds, four-component models reduced repeat error in six SEEG patients and 24 fMRI adults sci:sha256:1ffb0217c831625cbe8fc949585c14c1f283f7e9f1b2113e69122af88fa9a59b
Pinned sources and MIT preparation code; related repeat-prediction benchmark.
- usesSpeech and song axes gave positive mean repeat scores for nine voice clips in SEEG and two fMRI cohorts sci:sha256:6720e49a50bda02902607508181e2616c7f5e48b21bceee56a2d3fcdc618bdae
Original preparation code credited by the direct SCI source.
- usesOne bit per site gave sound match scores above chance in selected panels from six SEEG patients and 24 fMRI adults sci:sha256:4ee8594db22f3da99b83d6ec4e88c4f2e77b400cd193c2ba55b5f7c81946266c
Related one-bit reader retains site identity; the new reader removes target site order and global sign.
- doi:10.3389/fnins.2013.00174
- doi:10.1016/j.visres.2009.12.007
- doi:10.1016/j.neuroimage.2018.09.074
Cited by
3 publicationsPublic catalog entries on Sciscape.
- usesKeeping site labels improved fixed vocal class readers in six SEEG patients and 24 fMRI adults
We extend its question about removal of site labels from within-class repeat matching to a new excluded-example class reader. We read its outcomes before selecting this question.
- usesKeeping site labels improved repeated sound assignment after mean, size and global sign removal in six SEEG patients and 24 fMRI adults
Its sorted assignment assay and descriptive labelled magnitude result motivate the new projective signed comparison.
- Ranks matched nine vocal clips in selected SEEG and fMRI data; full-panel selection gave 62.9% matching in a noise model
Prior loss of site labels in sound matching defines a different feature-removal test. Catalog abstract inspected.