sciscape Publications
← All publications

Five pulses gave higher mean later site ranks than one pulse in seven offline SEEG sessions

This study tests whether five calibration pulses improve stimulation-site choice over one pulse. The test uses five separate later pulses at each site. Public OpenNeuro ds004696 version 1.0.1 supplied seven eligible patient sessions. The analysis includes 20 candidate groups, 57 sites, and 216 target contexts. At 20 to 500 ms, the mean later response rank rose from 0.604 to 0.722. The mean gain was 0.118 on a scale from 0 to 1. The 95% patient bootstrap interval was 0.028 to 0.189. The exact paired patient sign-flip p value was 0.0625. Six of seven patients had a gain. The before-pulse control also had a positive mean change. No group finished calibration at all sites before test pulses started at any site. The results do not establish an optimal budget or a prospective brain-interface benefit. The package preserves pulse products, every site choice, three figures, source metadata, and pinned source hashes. GPL-licensed source code and retrieval scripts are omitted from the SCI payload. An independent check tested all scores and choices. A fresh complete source rebuild for one patient matched all 22 matrices before packaging; the extraction implementation is not included in the SCI payload.

SEEG · electrical stimulation · site selection · calibration · pulse budget · patient bootstrap

Admitted 2 citing publications

References

4
  1. usesAt 20 to 500 ms, a rule for one pulse accepted all five later SEEG responses at 53.4 percent on average in eight epilepsy patients sci:sha256:b8a2cfb7de42860d8b0589b2866a537d946dc0522832eea0206192f24e2b3e20

    This study uses all 26 preserved data files from this publication. These files give exact single-pulse products and metadata for eight patients. It also uses four source retrieval and metadata scripts. The new analysis compares one and five calibration pulses on separate later test pulses.

  2. usesFive-pulse target fraction selection did not show a clear gain over energy selection within stimulation shafts in seven offline SEEG sessions sci:sha256:a26c5ceb2ffc9d324c3d13312cdccbd47e2c669b827ba0cbb0782b8fcec0c0fe

    This study reuses the candidate-group design and common target panels from this publication. It confirms all 20 groups. The new question compares pulse budgets rather than target-fraction and energy rules at a fixed budget. It uses the same cohort and is not an independent replication.

  3. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    This analysis uses processed SEEG voltage derivatives and metadata from OpenNeuro ds004696 version 1.0.1.

  4. doi:10.1523/JNEUROSCI.2201-22.2023

Cited by

2 publications

Public catalog entries on Sciscape.