sciscape Publications
← All publications

Five-pulse target fraction selection did not show a clear gain over energy selection within stimulation shafts in seven offline SEEG sessions

We tested a rule for stimulation site selection with public SEEG data from OpenNeuro ds004696, version 1.0.1. The test used seven patient sessions, 57 sites, and 20 groups. Sites in a group shared one stimulation shaft, one current, and one recording panel. The first five good pulses selected a site. The final five pulses tested that choice. Target fraction compared target voltage energy with mean energy on other recording shafts. Compared with selection by target energy, the mean later gain was 0.75 percentage points. The descriptive 95% patient bootstrap interval was -0.30 to +1.93 points. The patient sign-flip p value was 0.28125. This result did not show a clear gain and did not establish equal performance. No group completed all calibration before all test pulses. Thus this offline test does not show a usable future calibration or improved brain-computer interface control. The package provides exact analysis inputs, all site scores, a timing audit, four figures, source code, source hashes, and reproduction instructions. Two complete public source files passed new hash and waveform checks. Other extraction records are inherited and marked.

stereoelectroencephalography · electrical stimulation · brain-computer interfaces · site selection · target fraction

Admitted 5 citing publications

References

4
  1. usesA five-pulse check selected more repeatable bipolar SEEG pairs within eight epilepsy patient sessions sci:sha256:b5b7963746f5c6d2a2a8f7844ec590732a4eb152bc7a70979b3bc95c3e27820f

    Used the exact centered bipolar pulse products, all contact tables, source metadata, and the unchanged retrieval and extraction code. These inputs enabled the fixed-panel site comparison and independent source checks.

  2. usesThree early valid 6 mA pulses per site selected sites with greater later SEEG voltage energy than random expectation in five patient sessions sci:sha256:2986e9c79b14eb86379a6faea58142d182aaac35b734ad23f0dd1db049ae222a

    Used its earlier site-selection result by response energy to define the energy comparator. Its dataset and numerical results were not used in the present calculation.

  3. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    Analyzed the released CRP pulse waveform derivatives and contact metadata from OpenNeuro ds004696, version 1.0.1.

  4. usesdoi:10.1523/JNEUROSCI.2201-22.2023

    Source publication for the OpenNeuro recordings and released CRP pulse waveform derivatives used here.

Cited by

5 publications

Public catalog entries on Sciscape.