Five pulses preserved more later SEEG utility than random sets of the same size under uniform weights in seven offline sessions

This offline test used public SEEG data from OpenNeuro ds004696 version 1.0.1. It included seven patients, 57 stimulation sites, 20 groups, and 216 target contexts. A Pareto filter used the first five good pulses at each site. It kept sites with a target and off-target response tradeoff that another site did not dominate. The final five distinct pulses supplied evaluation scores. The test integrated the best later linear utility across uniform target weights from zero to one. Random reference sets had the same size as each retained set. The filter retained 74.3% of sites. Its mean utility advantage was 0.0340 normalized score units. The 95% patient bootstrap interval was 0.0163 to 0.0538. All seven patient means were positive. The filter still lost 0.0329 units against all later choices. Random sets lost 0.0670 units. No group placed all fit pulses before all evaluation pulses. This result supports an offline site-set benchmark. Online benefit remains untested. The package preserves data products, code, figures, an exact score method, source hashes, a fresh source audit, and reproduction instructions.

stereoelectroencephalography · electrical stimulation · Pareto filter · site selection · cross-pulse energy · offline benchmark

Admitted 0 citing publications

References

6
  1. usesCorrection with five pulses changed 40 of 217 site choices without a clear later gain at 20–500 ms in seven offline SEEG sessions sci:sha256:a8ed92c0b82fa2b3bc3de77ad0727223791f76401eeb5eb7b9643c5a294580b8

    Its cross-pulse energy correction informed the primary U score and the check with mean-waveform energy. This study uses the same public patient cohort and does not provide independent patient replication.

  2. usesFive-pulse target fraction selection did not show a clear gain over energy selection within stimulation shafts in seven offline SEEG sessions sci:sha256:a26c5ceb2ffc9d324c3d13312cdccbd47e2c669b827ba0cbb0782b8fcec0c0fe

    Its target-fraction analysis informed the use of common recording panels and equal weights across off-target shafts. This study evaluates sets of sites across linear utility weights instead of a single ratio-ranked site.

  3. usesFive pulses per site gave higher later 20–500 ms voltage scores than the nearest midpoint rule in seven offline SEEG sessions sci:sha256:5a3b0ef7c60d9ccb6ab72780104c08522d5c00ef2ac425835fefc99751512412

    This study imports its complete pulse Gram matrices, event metadata, provenance, and source retrieval code. It adds an offline Pareto site-set test with target and off-target objectives. The patient cohort is shared.

  4. usesA geometric median reduced 20–500 ms SEEG error with one simulated gain error among five calibration pulses in eight patients sci:sha256:c37805e37f6922e0de8e20f0231c72f98687698645324f2c0c6261e9d3ce9010

    The all-pulse products and retrieval code in the direct parent package came from this publication. Its metadata and source receipts are preserved as part of the data lineage.

  5. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    This study analyzes pulse derivatives from OpenNeuro ds004696 version 1.0.1.

  6. doi:10.1523/JNEUROSCI.2201-22.2023