A 25% random trial audit rate and a delay of five trials increased mean error exposure by 23.9 points against complete immediate feedback in eight offline SEEG tests
We tested how random trial audits and delayed labels affect a fixed SEEG error monitor. We used public OpenNeuro ds004473 version 1.0.2, eight reused recordings, 975 next-condition trials, and 961 accepted outputs with 248 errors. The readers and gates stayed fixed. The main setting used a 25% independent whole-trial audit rate and a delay of five retained trials. Complete immediate feedback was the reference. Mean person error exposure increased from 63.3% to 87.2%, a change of 23.9 percentage points. The descriptive 95% whole-person bootstrap interval was 9.5 to 37.9 points. Mask Monte Carlo standard error was 0.052 points. Across the fixed cohort, expected wrong delivered outputs increased from 99 to 184.4. Trial label requests fell from 574 to 208.2. Correct outputs withheld fell from 249 to 82.8. We scored 10,000 saved masks per person at five audit rates and three delays. A proof shows that independent audits and ordered fixed-delay feedback preserve the conditional false alarm bound for one fixed setting per reader. The bound needs a conditional count null and correct labels. No alarm does not certify low risk. All 162 source input files matched the sci manifest. Eight fresh pinned EDF ranges matched their hashes. Independent scalar checks passed in 4,200 cases, and a full numerical replay matched 21 files. The package preserves source features, raw retrieval recipes, code, masks, results, proof, three figures, and reproduction commands. This offline test does not establish a population effect, live device performance, or a brain stimulation result.
stereoelectroencephalography · brain-computer interface · error monitoring · random audits · delayed feedback · selective classification · conditional error bound
References
5- usesFixed early confidence thresholds reduced mean task state error to 24.5% at 49.6% retention after condition changes in eight offline SEEG tests sci:sha256:67664491c0474529f745f7fca563fcc1e5964887d611b1c9b90a66aa6e227ae6
We use the complete unchanged feature package, fixed primary reader values, calibration split, median confidence gates, public source metadata, raw range recipes, and independent reader checks. We reconstruct 975 test trial paths and add random audits with fixed feedback delays.
- usesEight fixed SEEG decoders scored 65.8% mean balanced accuracy for response versus rest windows after task condition changes sci:sha256:27c3a162d5f23c03418feb1337bb50c3dbd6fcf78da3fdc3bdc12da973491084
The gate source package preserves the feature arrays, fitted reader values, source extraction code, and source range receipts from this reader study. We use those fixed inputs without a new fit to test feedback schedules.
- usesA 10% conditional error test stopped five of eight fixed SEEG readers in an offline replay with complete trial feedback sci:sha256:b8f336970615995b4fd3dc2350ac36b69e5b2af03c114501eac711b39e682f50
We use the paired conditional error rule, 19 fixed mixture factors, 10% benchmark, threshold 160, and complete immediate feedback reference. We reproduce all eight reference stop positions and extend the replay to sparse whole-trial audits with delayed labels.
- usesdoi:10.18112/openneuro.ds004473.v1.0.2
This exact OpenNeuro dataset version supplies the eight SEEG recordings used in the fixed-record analysis.
- doi:10.1088/1741-2552%2Facae0a
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.