sciscape Publications
← All publications

Fixed early confidence thresholds reduced mean task state error to 24.5% at 49.6% retention after condition changes in eight offline SEEG tests

A brain reader can reject outputs with low confidence. We tested a fixed rejection rule in eight public SEEG recordings from OpenNeuro ds004473, version 1.0.2. We reused the same trials and fixed readers from an earlier publication. Each threshold was the confidence median from separate early data. The thresholds used 418 held-out trials in the first recorded condition. The next condition supplied 975 test trials. Mean task state error fell from 34.2% on all windows to 24.5% on accepted windows. Mean retention was 49.6%. Each person had lower accepted error. The mean reduction was 9.7 percentage points. Its descriptive 95% person bootstrap interval was 6.6 to 12.3 points. Equal weights for the two accepted states gave a 9.2-point reduction. The return check in three people did not reduce mean error. These saved event windows do not measure live command errors or stimulation control. Condition and time changed together. The inherited trial screen also used samples after the response. The package preserves source features, fixed models, predictions, figures, code, and independent checks.

selective classification · confidence threshold · rejection rule · stereo-EEG · brain-computer interface · condition shift · offline evaluation

Admitted 9 citing publications

References

5
  1. usesRemoving the test correction did not give a 10 percent error gate in eight offline SEEG recordings under a binomial trial model sci:sha256:09e14eac558a49e4a7ce5ae129799ee696dcadb2023ee12404803ea3c8a47851

    This strict error gate study defined a relevant limit. We tested mean error reduction and did not claim a certified error bound.

  2. usesEight fixed SEEG decoders scored 65.8% mean balanced accuracy for response versus rest windows after task condition changes sci:sha256:27c3a162d5f23c03418feb1337bb50c3dbd6fcf78da3fdc3bdc12da973491084

    We used this archive for all eight feature arrays, source metadata, primary fixed readers, and split records. It enabled a separate early threshold calibration and a later condition test.

  3. usesTrial resampling reduced offline error at 50 percent acceptance in eight SEEG recordings with 32 calibration trials sci:sha256:761ec71bb83cda1613335fce20a94d09f5c01d0eee0ceaf99b7c786619757ab9

    This batch rejection study motivated the confidence question. We tested thresholds fixed with separate early data. We did not reuse its resampling score or compare its different reader as a matched baseline.

  4. usesdoi:10.18112/openneuro.ds004473.v1.0.2

    Source SEEG data and metadata for the eight analyzed recordings; version 1.0.2 is identified in the publication and its archived source metadata.

  5. doi:10.1088/1741-2552%2Facae0a

Cited by

9 publications

Public catalog entries on Sciscape.