sciscape Publications
← All publications

A fixed SEEG reader gave 6.04 percent mean error reduction against a reference with the measured baseline after 20 calibration trials in six people

We tested whether earlier SEEG voltage improves a later pulse waveform forecast. The source was public OpenNeuro ds006065 version 1.0.0. Six people supplied eight blocks and 439 later test trials. Each fixed ridge reader used the first 20 pre-block trials. The input covered 150 ms. The target covered 50 to 250 ms after the inferred pulse. The reference included the measured input baseline. The mean error reduction was 6.04 percent. Its descriptive 95 percent person bootstrap interval was -0.28 to 15.20 percent. The exact sign-flip value was 0.21875. Four of six person means were positive. This test did not establish a consistent gain. Matched windows before pulses gave 7.02 percent mean reduction. Their gain was higher in all six people. This comparison is descriptive. An exact proof shows that the same baseline cancels from target and forecast error. An independent-input simulation showed 45.93 percent apparent gain against a constant corrected waveform. Its gain against the reference with the measured baseline was -1.88 percent. Thus, apparent gain can occur without future information. The package preserves four figures, compact inputs, models, predictions, full score tables, code, and retrieval instructions. All 16 complete source hashes were checked. A separate run reproduced all 12 forecast result files. The analysis uses reused clinical records and inferred timing. It does not test a causal neural response, a live controller, or clinical benefit.

SEEG · ridge regression · waveform forecasting · baseline correction · brain stimulation · electrophysiology · forecast evaluation

Admitted 0 citing publications

References

5
  1. usesA 500 ms past voltage sum gave a 63.26 degree error for centered theta phase 50 ms ahead in seven SEEG rest records sci:sha256:678ac0e1b4e8d00b5e72eb22a8e9bbbfc9c4bd67c224a77925cb4cba677fc26f

    We read its known-input benchmark after the local plan and used it to place the pulse baseline test in context. Our target is a baseline-corrected pulse waveform. We used none of that study's arrays or source code.

  2. usesCross-group tests did not establish SEEG response map change across six people sci:sha256:c1ee3af2654efdf1006112a9bbce8e06fd2be8451b3d580e001e611877e2e45f

    We used its pinned source manifest, retrieval and contact rules, and preserved original MATLAB archive. We extracted new raw voltage bins from complete source files. We used none of its response-map scores as new forecast outcomes.

  3. usesdoi:10.18112/openneuro.ds006065.v1.0.0

    The analysis used OpenNeuro ds006065 version 1.0.0; all 16 tested voltage files were retrieved and their full hashes matched the pinned Git-annex content keys.

  4. doi:10.1038/s41467-025-59417-7
  5. usesdoi:10.5281/zenodo.14735080

    The source MATLAB archive was consulted for contact, timing, and voltage-sign rules. Its GPL-3.0 archive is linked externally and omitted from this package.

Cited by

0 publications

Public catalog entries on Sciscape.