Distant 50-second EEG samples have larger RMS posterior theta-to-alpha log-ratio changes than adjacent selected samples in 88 ds004504 v1.0.9 recordings
This study measured temporal agreement of a fixed posterior theta-to-alpha power ratio in 88 OpenNeuro ds004504 v1.0.9 recordings. The channels were P3, P4, Pz, O1, and O2. The analysis used log ratios and kept each person as the statistical unit. The primary early and late samples each contained 100 seconds of selected EEG. Their concordance correlation coefficient was 0.840, with a 95 percent bootstrap interval of 0.756 to 0.900. Approximate late-to-early agreement factors were 0.533 to 2.196. Nine people had more than a twofold change. A planned secondary comparison used equal 50-second samples. The distant-to-adjacent RMS log-change ratio was 1.761, with an interval of 1.488 to 2.073. The bootstrap used 10,000 samples and kept diagnosis group counts. Adjacent means adjacent selected epochs. Source boundary exclusions can interrupt a sample. These results concern one recording per person and one preprocessing path. They do not identify a cause or measure reliability between visits. Fresh extraction matched preserved features for three source recordings. A separate analysis matched all eleven scientific output files exactly. The package preserves data, source hashes, code, results, and reproduction instructions.
electroencephalography · EEG · theta-to-alpha ratio · temporal agreement · concordance correlation · dementia · OpenNeuro
References
7- usesA fixed EEG model predicts shuffled labels when training and test sets share the 88 ds004504 subjects sci:sha256:7ba0bee1f809898d24fefdeb839b4d53689a26bcea0ff0429014af5f5ef0c2a9
This study reused the 1,760 epoch feature rows, epoch times, source manifest, metadata, extraction audit, and source extraction code. Verified archive hashes fixed these inputs. They enabled a new temporal agreement analysis in all 88 people. Fresh source replay checked one person per group.
- supersedesDistant 50-second EEG samples have larger RMS posterior theta-to-alpha log-ratio changes than adjacent selected samples in 88 ds004504 v1.0.9 recordings sci:sha256:24e1cc0fa403d29c5a1adf5039038cd8d72047cec749b7b8f472f26ad412a666
This version corrects the file check for the metadata folder added by sci fetch. All eleven scientific output files are unchanged. It preserves the full research package and replaces the first package version.
- usesdoi:10.18112/openneuro.ds004504.v1.0.9
The analysis used the exact OpenNeuro ds004504 v1.0.9 snapshot and preserved its source hashes and retrieval recipe.
- doi:10.3390/data8060095
- doi:10.1177/15500594261460590
- doi:10.2307/2532051
- doi:10.1016/S0140-6736(86)90837-8
Cited by
3 publicationsPublic catalog entries on Sciscape.
- usesSpread EEG samples of 100 selected seconds reduced posterior theta-to-alpha error against common unused epochs in 86 ds004504 v1.0.9 records
The earlier result showed larger posterior theta-to-alpha changes between distant EEG samples than between adjacent samples. It informed the sampling question and local plan. Its result tables were not analysis inputs.
- usesWelch tests that counted 20 EEG epochs per person as independent rejected 60.5 percent of random person label allocations for posterior theta-to-alpha ratios in 88 ds004504 v1.0.9 records
The prior posterior theta-to-alpha ratio definition informed the fixed measure in the local plan. Its result files were not used. This study tested statistical inference under random person labels.
- usesIndependent choices of 100 selected EEG seconds gave posterior theta-to-alpha AUC limits of 0.637 and 0.964 for 36 Alzheimer and 29 control ds004504 v1.0.9 records with common average reference
Its comparison of distant and adjacent posterior EEG samples informed the sample-choice question and local plan. Its result tables were not inputs. The present study gives attained AUC limits and an exact random-label expectation.