Surviving contrasts raised mean 20–100 ms condition accuracy from 71.24% to 73.15% after known simulated contact loss in eight SEEG patients with unchanged surviving signals

We tested whether a difference between surviving recording contacts can improve a fixed SEEG reader after one known simulated contact loss. We used eight patients from public STReEF data, OpenNeuro ds005448 version 1.0.0. Each patient had four known stimulation conditions, 20 calibration pulses, and 20 separate test pulses. Calibration selected four adjacent bipolar pairs. The reader used eight time coefficients per pair from 20 to 100 ms. All surviving voltages stayed unchanged. Each selected physical contact was made unavailable in turn. Mean accuracy was 71.24% after deletion of all affected pairs and 73.15% when the reader retained a contrast across a lost internal contact. The equal patient gain was 1.92 percentage points. Six of 58 contact cases permitted a bypass; all six improved. The descriptive 95% patient bootstrap interval was 0.54 to 3.79 points. The exact two-sided sign-flip value was 0.0625. This small test does not establish a population benefit. This result extends an earlier bypass study to another public dataset and a reader with calibration-selected pairs. The voltage identity and projection rule are prior mathematics. All 320 fresh raw range hashes matched. All 421,120 feature values were rebuilt exactly. Independent distances and a separate replay passed. The package has code, a direct contact reader, models, decisions, three figures, source records, and retrieval instructions. The split is retrospective. The test does not establish live interface performance.

SEEG · intracranial EEG · neural signal processing · contact loss · bipolar recording · fault tolerance · stimulation response · condition classification · epilepsy · calibration transfer

Admitted 2 citing publications

References

5
  1. usesBipolar bypass raised mean site accuracy from 28.4% to 31.9% at 20–100 ms after known simulated contact loss in five SEEG sessions with unchanged surviving voltages sci:sha256:909d106352dff262104732a7de573ab7f23dd4fed3a647b1aae6021979d02b41

    This earlier study supplied the bipolar bypass principle and general transferred-covariance proof. The present test adds STReEF data, calibration-selected pairs, a diagonal metric, and a checked direct contact reader. This work was found after the first new scores; the fixed plan and outcomes were kept.

  2. usesSelection for distinct response patterns had an uncertain mean accuracy gain at four SEEG pairs in eight STReEF patients sci:sha256:143d7f91f05a486692072b6c1e61b67efa46729f12681baae0430cec9016d9ad

    This work supplied the fixed STReEF sample, calibration selector, features, source records, and retrieval code. All 32 selected layouts and 640 nominal decisions matched. The new test uses known simulated physical contact loss.

  3. usesdoi:10.18112/openneuro.ds005448.v1.0.0

    This exact STReEF release supplied the eight SEEG patients used in the test.

  4. doi:10.1016/j.ynirp.2025.100274
  5. doi:10.1007/s12021-022-09567-6