Bipolar bypass raised mean site accuracy from 28.4% to 31.9% at 20–100 ms after known simulated contact loss in five SEEG sessions with unchanged surviving voltages

We tested one known simulated recording-contact loss in five public SEEG sessions from OpenNeuro ds004457 version 1.0.2. Surviving voltages stayed unchanged. The task was to identify a known stimulation site from its response at 20 to 100 ms. The bypass keeps intact bipolar pairs and adds a difference between surviving endpoints across the lost contact. It transfers calibrated means and covariance without a new fit. Six of 24 contact cases permitted a bypass; all six improved. The other cases were identical. Mean accuracy across all contact cases, with equal patient weight and zero credit for abstention, rose from 28.4% to 31.9%. Accuracy without loss was 40.6%. The gain was 3.50 percentage points. The descriptive patient bootstrap interval was 0.56 to 8.51 points; the exact two-sided sign-flip probability was 0.125. One patient supplied most of the gain. A proof shows that the map preserves all observable linear signals in a forest of calibrated pairs after one known loss. Public raw hashes, exact input and parent-prediction matches, fault invariance, independent score checks, and an exact repeat passed. The package preserves code, derived data, three figures, provenance, and a raw retrieval recipe. The reused cohort and offline split do not establish a population or online interface benefit.

stereoelectroencephalography · bipolar signals · contact loss · fault tolerance · site decoding · electrical stimulation · signal processing

Admitted 4 citing publications

References

4
  1. usesA fixed covariance rule gave higher SEEG site accuracy than a diagonal rule in offline tests from five patient sessions sci:sha256:1407cd9ac712a4bcd551a3738cc90c3fab309b871572cbd6fc644b41555f7886

    Used the calibration-only site means and fixed half residual-covariance, half diagonal fit. Transferred the frozen model to observable pair combinations after a known contact loss.

  2. usesRetained covariance gave 29.1 percent mean stimulation site accuracy after known simulated contact loss in five SEEG sessions sci:sha256:7d9856cbd13da084e7110eb2e7e7c7fcab41e64cbdb5b077cfc162a230169490

    Used the fixed recording contacts, eligible sites, pulse allocation, derived inputs, and retrieval and extraction code. Reproduced all no-loss and retained-pair predictions in three windows. Added a surviving-endpoint bypass and used zero credit for abstention as specified in the saved local plan.

  3. usesdoi:10.18112/openneuro.ds004457.v1.0.2

    This exact OpenNeuro dataset version supplied the five SEEG sessions and stimulation responses analyzed.

  4. doi:10.1523/JNEUROSCI.1325-22.2023

Cited by

4 publications

Public catalog entries on Sciscape.